2026 NEC Code Changes Update 10-Hours

Approved by the Maryland State Board of Electricians for Maryland Electricians License Renewal.

Yes! We Are Approved by the Maryland State Board of Electricians for Maryland Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2026 NEC Code Changes Update 10-Hours10.0 Code N/A 10/6/2026
-through-
10/6/2027
$99
-10

$89
This 10 Hour Maryland Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2026 NEC. From Article 90 Changes all the way through Annex L will be covered. This course will earn you 10 hours of electrical continuing education for your electrical license renewal in MD.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2026 NEC Code Changes Update 10-Hours Course Topics:
  • Global Changes. New Articles and Structure.
  • 90.3 Code Arrangement.
  • Article 100 Definitions. Grounding Electrode Bonding Jumper.
  • Article 100 Definitions. Limited-Energy System.
  • Article 100 Definitions. Power Control System (PCS).
  • Article 100 Definitions. Transformer Secondary Conductor.
  • Article 100 Definitions. Wiring Device.
  • 110.3(A)(8). Informational Note on Cybersecurity.
  • 110.3(B) Installation and Use.
  • 110.10 Available Fault Current, Short-Circuit Current Ratings, and Other Characteristics.
  • 110.16 Arc-Flash Hazard Marking.
  • 110.26 Spaces About Electrical Equipment.
  • 110.26(A)(1) Depth of Working Space.
  • 110.26(C)(2) Large Equipment.
  • 110.29 In Sight From (Within Sight).
  • Article 120 Branch-Circuit, Feeder, and Service Load Calculations.
  • 120.5 Calculations.
  • 120.13 Branch Circuit Loads at Dwelling Units.
  • Article 130 Energy Management Systems.
  • 210.8 GFCI Protection for Personnel.
  • 210.8(A) GFCI Protection at Dwelling Units.
  • 210.8(F) GFCI Protection for Outdoor Outlets.
  • 210.12(B) AFCI Protection at Dwelling Units.
  • 210.12(C) AFCI Protection at Dormitories.
  • 210.12(E) Branch Circuit Wiring Extensions, Modifications, or Replacements.
  • 210.52(A)(2)(1) Dwelling Unit Receptacles and Wall Space.
  • 210.52(A)(5) Receptacle Outlet Locations Prohibited.
  • 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  • 250.52(C)(4) Countertops and Work Surfaces.
  • 210.63(B) Service Receptacle for Other Electrical Equipment.
  • 210.70 Lighting Outlets Required.
  • 225.31 Disconnecting Means.
  • 225.41 Emergency Disconnects.
  • 230.67 Surge Protection.
  • 230.70(A)&(B) Service Disconnect Location and Marking.
  • 230.70(D) Identification of Other Source Disconnects.
  • 230.70(E) Service Equipment Replacement.
  • 230.85 Deletion of Emergency Dicsonnects.
  • 240.24(E) Overcurrent Devices in Bathrooms.
  • 250.64(C) Continuous GEC.
  • 250.64(G) Enclosures with Ventilation, Mounting, or Drainage Openings.
  • 250.109 Metal and Nonmetallic Enclosures.
  • 250.118 Types of Equipment Grounding Conductors.
  • 300.4(C) Damaged Conductors and Wiring Methods.
  • 300.6(E) Wiring Methods and Materials in or Under Roof Decking.
  • 300.6(G) Fittings.
  • 300.9 Raceways Exposed to Different Temperatures.
  • 300.13(B) &(C) Securing and Supporting Wiring Systems Installed Above Suspended Ceilings.
  • 300.13(E) Cable Ties Used as Means of Securement and Support.
  • 300.20 Raceway Installations.
  • 310.10(D)Conductors Exposed to Direct Sunlight.
  • 310.14(A)(2) Selection of Conductor Ampacity.
  • Ampacity Table 310.16.
  • 312.8(C) Cables Entering Cabinets Cutout Boxes and Meter Socket Enclosures.
  • 312.11(A) Splices, Taps, and Feed-Through Conductors.
  • 314.5 Nonmetallic Boxes.
  • 314.22 Surface Extensions.
  • 314.23(E) Raceway-Supported Enclosures Without Devices or Luminaires.
  • 314.23(F) Raceway-Supported Enclosures With Devices or Luminaires.
  • 314.27(B) Boxes at Ceiling-Suspended (Paddle) Fan Outlets.
  • 334.10(3) Uses Permitted.
  • 334.24 Bending Radius.
  • 336.10 Tray Cable Uses Permitted.
  • 344.29 Terminations.
  • 392.18(F) Cable Tray Access.
  • 404.1(A) Switches Covered.
  • 404.30 Switch Enclosures with Doors or Hinged Covers.
  • 406.1 Wiring Devices.
  • 406.10 Wiring Device Terminations.
  • 406.12(D) Receptacle Replacements.
  • 406.26 Tamper-Resistant Receptacles.
  • 408.6 Short-Circuit Current Rating.
  • 408.10(F) Switchboard, Switchgear, or Panelboard Identification.
  • 422.12 Central Heating Equipment.
  • 430.98(A) Motor Control Center Marking.
  • 440.11 HVAC Disconnecting Means.
  • 440.15 Split-System Indoor Unit Identification.
  • 445.19 Generator Remote Emergency Shutdown.
  • 450.12(A) Grounding and Bonding Dry-Type Transformer Enclosures.
  • 517.15 Multiwire Branch Circuits.
  • 550.51(E) Surge Protection at Replacement Mobile Homes or Manufactured Homes.
  • 555.15 Servicing and Replacing of Equipment.
  • 620.16(C) Elevator Control Panel Field Marking.
  • 620.51(E) Surge Protection.
  • 625.5 EVSE Field Markings.
  • 625.43 EVSE Disconnecting Means.
  • 680.26(B) Equipotential Bonding.
  • 680.26(B)(2) Perimeter Surfaces.
  • 690.12 Rapid Shutdown of PV Systems on Buildings.
  • 695.7(A) Power Wiring.
  • 700.4(F) Temporary Source of Power for Servicing of the Alternate Source of Power.
  • 700.11(D) Wiring Protection of Class 2 and Class 4 Powered Emergency Lighting Systems.
  • 700.12(G) Battery-Equipped Emergency Luminaires.
  • 705.11 Source Connections to a Service.
  • 705.13 Power Control Systems (PCSs).
  • 706.15(B) ESS Disconnecting Means Location and Control.
  • New Chapter 7 Articles for Limited Energy System Wiring Methods and Materials.
  • Article 725 Class 2 and Class 3 Power-Limited Circuits.
  • Chapter 8 General Requirements for Communications Systems Outside and Entering Buildings.
  • Annex L Proposed Organization of the 2029 National Electrical Code.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other MD Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2023 Code Changes Update - 5 Hours Banner
NEC 2023 Code Changes Update - 5 Hours
Credit Type: Code
Credit Hours: 5.0
Price: $55
 
NEC 2026 Code Changes Update 5-hours Banner
NEC 2026 Code Changes Update 5-hours
Credit Type: Code
Credit Hours: 5.0
Price: $55
 
NEC 2023 Code Changes Update - 10 Hours Banner
NEC 2023 Code Changes Update - 10 Hours
Credit Type: Code
Credit Hours: 10.0
Price: $99
 
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Credit Type: Code
Credit Hours: 5.0
Price: $55
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
Boxes and Enclosures (Webinar) Banner
Boxes and Enclosures (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
NEC 2020 Code Changes Update - 10 Hours Banner
NEC 2020 Code Changes Update - 10 Hours
Credit Type: Code
Credit Hours: 10.0
Price: $99
 
2026 NEC Code Changes Update 10-Hours Banner
2026 NEC Code Changes Update 10-Hours
Credit Type: Code
Credit Hours: 10.0
Price: $99
 
Passing the Electrical Inspection (Webinar) Banner
Passing the Electrical Inspection (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75