2023 Available Fault Current with TX Safety & Laws

Approved by the Texas Department of Licensing and Regulation - Electrical for Texas Electricians License Renewal.

Yes! We Are Approved by the Texas Department of Licensing and Regulation - Electrical for Texas Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 Available Fault Current with TX Safety & Laws
NO TEST. No passing score needed.
4.0 NEC / Safety / Laws 33240 9/9/2026
-through-
9/9/2027
$35
-11

$24
This 4-hour online electrical continuing education license renewal course covers available fault current requirements for electrical installations in accordance with the National Electrical Code. Students will learn about available fault current, series rated systems, fully rated systems, interrupting ratings, and short-circuit current ratings in accordance with the NEC. This course takes the difficult topics of available fault current, short circuit current ratings, fully rated and series rated electrical systems and places them in an easy to understand format. This course also provides Texas laws, rules, and safety to provide 4 hours towards your Texas license renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 Available Fault Current with TX Safety & Laws Course Topics:
  • Available Fault Current.
  • Available Fault Current and Characteristics of the Circuit.
  • Article 100 Definitions. Interrupting Rating.
  • Article 100 Definitions. Short Circuit Current Rating.
  • 110.9 Interrupting Rating of Defensive and Passive Devices.
  • 110.9 Interrupting Rating.
  • 240.83(C) Circuit Breaker Marking. Interrupting Rating.
  • 110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  • Available Fault Current. Applying It Downstream of the Service.
  • 110.24(A) Available Fault Current. Field Marking.
  • 110.24(B) Available Fault Current. Modifications.
  • Available Fault Current and Remodel or Service Work.
  • Available Fault Current and Blueprints.
  • Available Fault Current on the Plans. Exercise 1.
  • Available Fault Current on the Plans. Exercise 2.
  • Available Fault Current on the Plans. Exercise 3.
  • Fully Rated Systems.
  • Series Rated Systems.
  • 240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  • 110.22(B) Engineered Series Combination Systems.
  • 240.86(B) Series Rated Systems. Tested Combinations.
  • 110.22(C) Tested Series Combination Systems.
  • Verifying a Tested Series Rated Combination. Circuit Breakers.
  • Verifying a Tested Series Rated Combination. Fuses.
  • NEC 110.3(B) and The Intermixing of Circuit breakers.
  • Fuses Protecting Circuit Breakers.
  • Fuse Protection of Passive Components.
  • Selecting a Fuse Because of its Current Limiting Characteristics.
  • Short-Circuit Current Ratings Dependent on Specific OCPDs.
  • Surge-Protective Devices. Short-Circuit Current Rating.
  • Article 100 & 409.22 Industrial Control Panels.
  • 409.110 Industrial Control Panels. Marking.
  • 440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  • 440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  • 620.16 Elevators. Short-Circuit Current Rating.
  • Texas Laws and Rules 73.10. Definitions.
  • Texas Laws and Rules 73.10. Definitions.
  • Texas Laws and Rules 73.10. Definitions.
  • Texas Laws and Rules 73.20. Licensing Requirements--Applicant and Experience Requirements.
  • Texas Laws and Rules 73.22. Licensing Requirements-General.
  • Texas Laws and Rules 73.23. Licensing Requirements--Renewal.
  • Texas Laws and Rules 73.25. Continuing Education.
  • Texas Laws and Rules Sec. 1305.002. Definitions.
  • Texas Laws and Rules Sec. 1305.002. Definitions.
  • Texas Laws and Rules Sec. 1305.003. Exemptions; Application of Chapter.
  • NFPA 70E 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 1.
  • NFPA 70E 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 2.
  • NFPA 70E 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 3.
  • NFPA 70E 130.7(C)(15)(a) Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems. Exercise 1.
  • NFPA 70E 130.5(C)(15)(a) Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems. Exercise 2.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other TX Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2026 Code Changes Update TX Safety & Laws Banner
NEC 2026 Code Changes Update TX Safety & Laws
Course #: 31983
Credit Type: NEC / Safety / Laws
Credit Hours: 4.0
Price: $35
 
2023 NEC Code Changes with Safety & TX Laws Banner
2023 NEC Code Changes with Safety & TX Laws
Course #: 32603
Credit Type: NEC / Safety / Laws
Credit Hours: 4.0
Price: $35
 
Passing the Inspection with Safety & TX Laws Banner
Passing the Inspection with Safety & TX Laws
Course #: 32401
Credit Type: NEC / Safety / Laws
Credit Hours: 4.0
Price: $35
 
2023 Available Fault Current with TX Safety & Laws Banner
2023 Available Fault Current with TX Safety & Laws
Course #: 33240
Credit Type: NEC / Safety / Laws
Credit Hours: 4.0
Price: $35