Available Fault Current

Approved by the Montana State Electrical Board for Montana Electricians License Renewal.

Yes! We Are Approved by the Montana State Electrical Board for Montana Electricians' License Renewal.

Montana Electrical Board Continuing Education Provider License#: ELE-CEP-LIC-43014
Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
Available Fault Current4.0 Code ELE-CE-CRS-01407 7/24/2026
-through-
8/1/2028
$49
-14

$35
This 4 hour Montana Electrical Continuing Education License Renewal Course takes the difficult topics of available fault current, short circuit current ratings, fully rated and series rated electrical systems and places them in an easy to understand format. This course will earn you 4 hours of electrical continuing education of credit type 'Industry Related' for your electrical license renewal in Montana.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Available Fault Current Course Topics:
  • Available Fault Current.
  • Available Fault Current and Characteristics of the Circuit.
  • Available Fault Current. Understanding the Calculations.
  • Available Fault Current. Example Calculation.
  • Article 100 Definitions. Interrupting Rating.
  • Article 100 Definitions. Short Circuit Current Rating.
  • 110.9 Interrupting Rating of Defensive and Passive Devices.
  • 110.9 Interrupting Rating.
  • 240.83(C) Circuit Breaker Marking. Interrupting Rating.
  • 110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  • Available Fault Current. Applying It Downstream of the Service.
  • 110.16(A) Arc-Flash Hazard Warning. General.
  • 110.16(B) Arc-Flash Hazard Warning. Service Equipment.
  • 110.24(A) Available Fault Current. Field Marking.
  • 110.24(B) Available Fault Current. Modifications.
  • Available Fault Current and Remodel or Service Work.
  • Available Fault Current and Blueprints.
  • Available Fault Current on the Plans. Exercise 1.
  • Available Fault Current on the Plans. Exercise 2.
  • Available Fault Current on the Plans. Exercise 3.
  • Available Fault Current on the Plans. Exercise 4.
  • Fully Rated Systems.
  • Series Rated Systems.
  • 240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  • 110.22(B) Engineered Series Combination Systems.
  • 240.86(B) Series Rated Systems. Tested Combinations.
  • 110.22(C) Tested Series Combination Systems.
  • Verifying a Tested Series Rated Combination. Circuit Breakers.
  • Verifying a Tested Series Rated Combination. Fuses.
  • NEC 110.3(B) and The Intermixing of Circuit breakers.
  • 240.86(C) Series Ratings. Motor Contribution Exercise 1.
  • 240.86(C) Series Ratings. Motor Contribution Exercise 2.
  • Series Ratings and Selective Coordination.
  • Circuit Breakers Protecting Circuit Breakers.
  • Fuses Protecting Circuit Breakers.
  • Fuse Protection of Passive Components.
  • Selecting a Fuse Because of its Current Limiting Characteristics.
  • Short-Circuit Current Ratings Dependent on Specific OCPDs.
  • 230.82(3) Equipment Connected to the Supply Side of Service Disconnect.
  • Surge-Protective Devices. Short-Circuit Current Rating.
  • Article 100 & 409.22 Industrial Control Panels.
  • 409.110 Industrial Control Panels. Marking.
  • 430.8 Marking on Motor Controllers.
  • 430.99 Motor Control Centers. Available Fault Current.
  • 440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  • 440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  • 480.7 DC Disconnect Methods. Maximum Available Short-Circuit Current.
  • 620.16 Elevators. Short-Circuit Current Rating.
  • 700.5(E) Emergency System Transfer Equipment. Documentation.
  • 701.4 Legally Required Standby Systems. Capacity and Rating.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other MT Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2026 Code Changes Update – 16 Hours Banner
NEC 2026 Code Changes Update – 16 Hours
Course #: ELE-CE-CRS-01419
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2026 Code Changes Update – 8 Hours Banner
NEC 2026 Code Changes Update – 8 Hours
Course #: ELE-CE-CRS-01420
Credit Type: Code
Credit Hours: 8.0
Price: $69
 
Available Fault Current Banner
Available Fault Current
Course #: ELE-CE-CRS-01407
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
NEC 2020 Code Changes Update - 16 Hours Banner
NEC 2020 Code Changes Update - 16 Hours
Course #: ELE-CE-CRS-001406
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2020 Code Changes Update - 8 Hours Banner
NEC 2020 Code Changes Update - 8 Hours
Course #: ELE-CE-CRS-01405
Credit Type: Code
Credit Hours: 8.0
Price: $69
 
NEC 2023 Code Changes Update - 16 Hours Banner
NEC 2023 Code Changes Update - 16 Hours
Course #: ELE-CE-CRS-01411
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2023 Code Changes Update - 8 Hours Banner
NEC 2023 Code Changes Update - 8 Hours
Course #: ELE-CE-CRS-01410
Credit Type: Code
Credit Hours: 8.0
Price: $69