Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2026 Code Changes Update – 8 Hours8.0 Code ELE-CE-CRS-01420 7/24/2026
-through-
8/1/2028
$69
-10

$59
This Montana Electrical Continuing Education License Renewal Course reviews the most important updated 2026 NEC Changes in detail. Course earns you 8 hours of electrical continuing education of credit type CODE for your electrical license renewal with the MT State Electrical Board. In this course we will review all of the most important National Electrical Code changes you will encounter at work. From Article 90 through Annex L is covered.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2026 Code Changes Update – 8 Hours Course Topics:
  • Global Changes. New Articles and Structure.
  • 90.3 Code Arrangement.
  • Article 100 Definitions. Grounding Electrode Bonding Jumper.
  • Article 100 Definitions. Power Control System (PCS).
  • Article 100 Definitions. Transformer Secondary Conductor.
  • Article 100 Definitions. Wiring Device.
  • 110.3(B) Installation and Use.
  • 110.10 Available Fault Current, Short-Circuit Current Ratings, and Other Characteristics.
  • 110.16 Arc-Flash Hazard Marking.
  • 110.26 Spaces About Electrical Equipment.
  • Article 120 Branch-Circuit, Feeder, and Service Load Calculations.
  • 210.8 GFCI Protection for Personnel.
  • 210.8(A) GFCI Protection at Dwelling Units.
  • 210.8(F) GFCI Protection for Outdoor Outlets.
  • 210.12(B) AFCI Protection at Dwelling Units.
  • 210.12(E) Branch Circuit Wiring Extensions, Modifications, or Replacements.
  • 210.52(A)(2)(1) Dwelling Unit Receptacles and Wall Space.
  • 210.52(A)(5) Receptacle Outlet Locations Prohibited.
  • 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  • 250.52(C)(4) Countertops and Work Surfaces.
  • 210.63(B) Service Receptacle for Other Electrical Equipment.
  • 225.31 Disconnecting Means.
  • 225.41 Emergency Disconnects.
  • 230.67 Surge Protection.
  • 230.70(A)&(B) Service Disconnect Location and Marking.
  • 230.70(D) Identification of Other Source Disconnects.
  • 230.70(E) Service Equipment Replacement.
  • 230.85 Deletion of Emergency Dicsonnects.
  • 250.64(C) Continuous GEC.
  • 250.64(G) Enclosures with Ventilation, Mounting, or Drainage Openings.
  • 300.6(E) Wiring Methods and Materials in or Under Roof Decking.
  • 300.6(G) Fittings.
  • 300.13(E) Cable Ties Used as Means of Securement and Support.
  • 300.20 Raceway Installations.
  • 310.10(D)Conductors Exposed to Direct Sunlight.
  • 310.14(A)(2) Selection of Conductor Ampacity.
  • 312.8(C) Cables Entering Cabinets Cutout Boxes and Meter Socket Enclosures.
  • 312.11(A) Splices, Taps, and Feed-Through Conductors.
  • 314.5 Nonmetallic Boxes.
  • 314.22 Surface Extensions.
  • 314.23(E) Raceway-Supported Enclosures Without Devices or Luminaires.
  • 314.23(F) Raceway-Supported Enclosures With Devices or Luminaires.
  • 314.27(B) Boxes at Ceiling-Suspended (Paddle) Fan Outlets.
  • 334.10(3) Uses Permitted.
  • 334.24 Bending Radius.
  • 336.10 Tray Cable Uses Permitted.
  • 392.18(F) Cable Tray Access.
  • 404.1(A) Switches Covered.
  • 404.30 Switch Enclosures with Doors or Hinged Covers.
  • 406.1 Wiring Devices.
  • 406.10 Wiring Device Terminations.
  • 406.12(D) Receptacle Replacements.
  • 406.26 Tamper-Resistant Receptacles.
  • 408.6 Short-Circuit Current Rating.
  • 430.98(A) Motor Control Center Marking.
  • 440.11 HVAC Disconnecting Means.
  • 440.15 Split-System Indoor Unit Identification.
  • 450.12(A) Grounding and Bonding Dry-Type Transformer Enclosures.
  • 550.51(E) Surge Protection at Replacement Mobile Homes or Manufactured Homes.
  • 555.15 Servicing and Replacing of Equipment.
  • 625.5 EVSE Field Markings.
  • 625.43 EVSE Disconnecting Means.
  • 680.26(B) Equipotential Bonding.
  • 680.26(B)(2) Perimeter Surfaces.
  • 690.12 Rapid Shutdown of PV Systems on Buildings.
  • 695.7(A) Power Wiring.
  • 700.4(F) Temporary Source of Power for Servicing of the Alternate Source of Power.
  • 700.11(D) Wiring Protection of Class 2 and Class 4 Powered Emergency Lighting Systems.
  • 700.12(G) Battery-Equipped Emergency Luminaires.
  • 705.11 Source Connections to a Service.
  • 706.15(B) ESS Disconnecting Means Location and Control.
  • New Chapter 7 Articles for Limited Energy System Wiring Methods and Materials.
  • Article 725 Class 2 and Class 3 Power-Limited Circuits.
  • Chapter 8 General Requirements for Communications Systems Outside and Entering Buildings.
  • Annex L Proposed Organization of the 2029 National Electrical Code.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other MT Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2026 Code Changes Update – 16 Hours Banner
NEC 2026 Code Changes Update – 16 Hours
Course #: ELE-CE-CRS-01419
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2026 Code Changes Update – 8 Hours Banner
NEC 2026 Code Changes Update – 8 Hours
Course #: ELE-CE-CRS-01420
Credit Type: Code
Credit Hours: 8.0
Price: $69
 
Available Fault Current Banner
Available Fault Current
Course #: ELE-CE-CRS-01407
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
NEC 2020 Code Changes Update - 16 Hours Banner
NEC 2020 Code Changes Update - 16 Hours
Course #: ELE-CE-CRS-001406
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2020 Code Changes Update - 8 Hours Banner
NEC 2020 Code Changes Update - 8 Hours
Course #: ELE-CE-CRS-01405
Credit Type: Code
Credit Hours: 8.0
Price: $69
 
NEC 2023 Code Changes Update - 16 Hours Banner
NEC 2023 Code Changes Update - 16 Hours
Course #: ELE-CE-CRS-01411
Credit Type: Code
Credit Hours: 16.0
Price: $119
 
NEC 2023 Code Changes Update - 8 Hours Banner
NEC 2023 Code Changes Update - 8 Hours
Course #: ELE-CE-CRS-01410
Credit Type: Code
Credit Hours: 8.0
Price: $69