Available Fault Current

Accepted by the South Carolina State Board of Registration for Professional Engineers and Surveyors for South Carolina Electrical Engineers License Renewal.

Yes! We Are Accepted by the South Carolina State Board of Registration for Professional Engineers and Surveyors for South Carolina Electrical Engineers' License Renewal.

Electrical Engineer Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
Available Fault Current4.0 NEC N/A 5/29/2024
-through-
6/3/2027
$50
This 4 hour South Carolina Electrical Engineer Professional Development License Renewal Course takes the difficult topics of available fault current, short circuit current ratings, fully rated and series rated electrical systems and places them in an easy to understand format. This course will earn you 4 hours of CEU credits which is worth 4 PDHs for your license.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Available Fault Current Course Topics:
  • Available Fault Current.
  • Available Fault Current and Characteristics of the Circuit.
  • Available Fault Current. Understanding the Calculations.
  • Available Fault Current. Example Calculation.
  • Article 100 Definitions. Interrupting Rating.
  • Article 100 Definitions. Short Circuit Current Rating.
  • 110.9 Interrupting Rating of Defensive and Passive Devices.
  • 110.9 Interrupting Rating.
  • 240.83(C) Circuit Breaker Marking. Interrupting Rating.
  • 110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  • Available Fault Current. Applying It Downstream of the Service.
  • 110.16(A) Arc-Flash Hazard Warning. General.
  • 110.16(B) Arc-Flash Hazard Warning. Service Equipment.
  • 110.24(A) Available Fault Current. Field Marking.
  • 110.24(B) Available Fault Current. Modifications.
  • Available Fault Current and Remodel or Service Work.
  • Available Fault Current and Blueprints.
  • Available Fault Current on the Plans. Exercise 1.
  • Available Fault Current on the Plans. Exercise 2.
  • Available Fault Current on the Plans. Exercise 3.
  • Available Fault Current on the Plans. Exercise 4.
  • Fully Rated Systems.
  • Series Rated Systems.
  • 240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  • 110.22(B) Engineered Series Combination Systems.
  • 240.86(B) Series Rated Systems. Tested Combinations.
  • 110.22(C) Tested Series Combination Systems.
  • Verifying a Tested Series Rated Combination. Circuit Breakers.
  • Verifying a Tested Series Rated Combination. Fuses.
  • NEC 110.3(B) and The Intermixing of Circuit breakers.
  • 240.86(C) Series Ratings. Motor Contribution Exercise 1.
  • 240.86(C) Series Ratings. Motor Contribution Exercise 2.
  • Series Ratings and Selective Coordination.
  • Circuit Breakers Protecting Circuit Breakers.
  • Fuses Protecting Circuit Breakers.
  • Fuse Protection of Passive Components.
  • Selecting a Fuse Because of its Current Limiting Characteristics.
  • Short-Circuit Current Ratings Dependent on Specific OCPDs.
  • 230.82(3) Equipment Connected to the Supply Side of Service Disconnect.
  • Surge-Protective Devices. Short-Circuit Current Rating.
  • Article 100 & 409.22 Industrial Control Panels.
  • 409.110 Industrial Control Panels. Marking.
  • 430.8 Marking on Motor Controllers.
  • 430.99 Motor Control Centers. Available Fault Current.
  • 440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  • 440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  • 480.7 DC Disconnect Methods. Maximum Available Short-Circuit Current.
  • 620.16 Elevators. Short-Circuit Current Rating.
  • 700.5(E) Emergency System Transfer Equipment. Documentation.
  • 701.4 Legally Required Standby Systems. Capacity and Rating.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other SC Technicians took these engineer continuing education courses with us:
Click on a banner below to go to the page for that course
Available Fault Current Banner
Available Fault Current
Credit Type: NEC
Credit Hours: 4.0
Price: $50
 
2023 NEC Code Changes Update part 1 Banner
2023 NEC Code Changes Update part 1
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
2023 NEC Code Changes Update part 2 Banner
2023 NEC Code Changes Update part 2
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
Ethics in Engineering Banner
Ethics in Engineering
Credit Type: Ethics
Credit Hours: 2.0
Price: $25
 
NEC 2017 Code Changes Update Part 1 Banner
NEC 2017 Code Changes Update Part 1
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
NEC 2017 Code Changes Update Part 2 Banner
NEC 2017 Code Changes Update Part 2
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
Passing the Inspection Banner
Passing the Inspection
Credit Type: NEC
Credit Hours: 4.0
Price: $50