2026 NEC Code Changes Update Part 1

Approved by the South Dakota Electrical Commission Department of Labor & Regulation for South Dakota Electricians License Renewal.

Yes! We Are Approved by the South Dakota Electrical Commission Department of Labor & Regulation for South Dakota Electricians' License Renewal.

South Dakota Electrical Board Continuing Education Provider License#: 152
Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2026 NEC Code Changes Update Part 18.0 Code 6939 3/2/2026
-through-
8/31/2027
$79
-20

$59
This South Dakota Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2026 NEC. From Article 90 all the way through Section 300.20 will be covered. This course is great to learn all the new ideas from the 2026 NEC. After completing this course, the licensee will be able to apply NEC changes from what they have learned from topics ranging from Article 90 all the way through Article 300. This increases in effectiveness if combined with Part 2.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2026 NEC Code Changes Update Part 1 Course Topics:
  • Global Changes. New Articles and Structure.
  • 90.3 Code Arrangement.
  • Article 100 Definitions. Grounding Electrode Bonding Jumper.
  • Article 100 Definitions. Cable, Limited-Energy. (Limited-Energy Cable)
  • Article 100 Definitions. Cable Tie. Cable Tie Fixing Device.
  • Article 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose (SPGFCI).
  • Article 100 Definitions. Limited-Energy System.
  • Article 100 Definitions. Overcurrent Protective Device.
  • Article 100 Definitions. Deletion of “Panelboard Enclosed”.
  • Article 100 Definitions. Power Control System (PCS).
  • Article 100 Definitions. Transformer Secondary Conductor.
  • Article 100 Definitions. Wiring Device.
  • 110.3(A)(8). Informational Note on Cybersecurity.
  • 110.3(B) Installation and Use.
  • 110.10 Available Fault Current, Short-Circuit Current Ratings, and Other Characteristics.
  • 110.16 Arc-Flash Hazard Marking.
  • 110.26 Spaces About Electrical Equipment.
  • 110.26(A) Working Space.
  • 110.26(A)(1) Depth of Working Space.
  • 110.26(C)(2) Large Equipment.
  • 110.29 In Sight From (Within Sight).
  • Article 120 Branch-Circuit, Feeder, and Service Load Calculations.
  • 120.5 Calculations.
  • 120.7 Power Control Systems.
  • 120.13 Branch Circuit Loads at Dwelling Units.
  • 120.54 Electric Clothes Dryers -Dwelling Units.
  • Article 130 Energy Management Systems.
  • Article 206 Non-Power-Limited Remote-Control and Signaling Circuits.
  • Article 210 Branch Circuits.
  • 210.8 GFCI Protection for Personnel.
  • 210.8(A) GFCI Protection at Dwelling Units.
  • 210.8(F) GFCI Protection for Outdoor Outlets.
  • 210.12(B) AFCI Protection at Dwelling Units.
  • 210.12(C) AFCI Protection at Dormitories.
  • 210.12(E) Branch Circuit Wiring Extensions, Modifications, or Replacements.
  • 210.22 & 210.23 Permissible loads and 10-amp Branch Circuits.
  • 210.52(A)(2)(1) Dwelling Unit Receptacles and Wall Space.
  • 210.52(A)(5) Receptacle Outlet Locations Prohibited.
  • 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  • 250.52(C)(4) Countertops and Work Surfaces.
  • 210.63(B) Service Receptacle for Other Electrical Equipment.
  • 210.70 Lighting Outlets Required.
  • 215.12(C) Feeder Identification.
  • 215.18 Surge Protection.
  • 225.31 Disconnecting Means.
  • 225.41 Emergency Disconnects.
  • 230.46 Spliced and Tapped Conductors.
  • 230.66 Marking.
  • 230.67 Surge Protection.
  • 230.70(A)&(B) Service Disconnect Location and Marking.
  • 230.70(D) Identification of Other Source Disconnects.
  • 230.70(E) Service Equipment Replacement.
  • 230.82 Equipment Connected to the Supply Side of Service Disconnect.
  • 230.85 Deletion of Emergency Dicsonnects.
  • 230.95 Ground-Fault Protection of Equipment (GFPE).
  • 240.24(E) Overcurrent Devices in Bathrooms.
  • 250.1 & 250.4 Grounding and Bonding Scope, and General Requirements.
  • 250.8(A) Permitted Methods of Grounding and Bonding.
  • 250.64(C) Continuous GEC.
  • 250.64(G) Enclosures with Ventilation, Mounting, or Drainage Openings.
  • 250.94(A) Intersystem Bonding Termination (IBT) Devices.
  • 250.109 Metal and Nonmetallic Enclosures.
  • 250.118 Types of Equipment Grounding Conductors.
  • Article 265 Branch Circuits Over 1000 Volts ac, 1500 Volts dc, Nominal.
  • Article 266 Feeders Over 1000 Volts ac, 1500 Volts dc, Nominal.
  • Article 267 Outside Branch Circuits and Feeders Over 1000 Volts ac, 1500 Volts dc, Nominal.
  • Article 268 Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
  • Article 270 Grounding and Bonding of Systems over 1000 Volts ac, 1500 Volts dc, Nominal.
  • 300.4(C) Damaged Conductors and Wiring Methods.
  • 300.6(E) Wiring Methods and Materials in or Under Roof Decking.
  • 300.6(G) Fittings.
  • 300.9 Raceways Exposed to Different Temperatures.
  • 300.13(B) &(C) Securing and Supporting Wiring Systems Installed Above Suspended Ceilings.
  • 300.13(E) Cable Ties Used as Means of Securement and Support.
  • 300.20 Raceway Installations.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other SD Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2026 NEC Code Changes Update Part 1 Banner
2026 NEC Code Changes Update Part 1
Course #: 6939
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
2023 NEC Code Changes Update part 1 Banner
2023 NEC Code Changes Update part 1
Course #: 6610
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
2026 NEC Code Changes Update Part 2 Banner
2026 NEC Code Changes Update Part 2
Course #: 6940
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
2023 NEC Code Changes Update part 2 Banner
2023 NEC Code Changes Update part 2
Course #: 6611
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Course #: 6715
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Course #: 6716
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Course #: 6719
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Boxes and Enclosures (Webinar) Banner
Boxes and Enclosures (Webinar)
Course #: 6718
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Passing the Inspection (Webinar) Banner
Passing the Inspection (Webinar)
Course #: 6717
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Course #: 6714
Credit Type: Code
Credit Hours: 4.0
Price: $75