Grounding & NEC Fundamentals

Approved by the DBPR Electrical Contractors' Licensing Board for Florida Electricians License Renewal.

Yes! We Are Approved by the DBPR Electrical Contractors' Licensing Board for Florida Electricians' License Renewal.

Florida Electrical Board Continuing Education Provider License#: 0007582
Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
Grounding & NEC Fundamentals6.0 Technical (T) 0803212 8/17/2026
-through-
5/31/2027
$69
-10

$59
This Florida Electrical Continuing Education License Renewal Course reviews the most important grounding and bonding requirements from the 2023 NEC and also addresses basic electrical fundamentals the electrician needs to know. Earns 6 hours of Electrical Continuing Education for Electrical License Renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Grounding & NEC Fundamentals Course Topics:
  • NEC Article 250.
  • Grounded.
  • Article 100 Definitions. Grounded Conductor.
  • Grounded Conductor.
  • Grounding Versus Bonding.
  • Equipment Grounding Conductors.
  • Article 100. Bonding Jumper, Main.
  • Article 100. Bonding Jumper, Supply-Side.
  • 250.12 Clean Surfaces.
  • 250.24(B) Load-Side Grounding Connections.
  • 250.25 Grounding of Systems Permitted to Be Connected on the Supply Side of the Service Disconnect.
  • 250.28(A) Main Bonding Jumper and System Bonding Jumper Material.
  • 250.30 Grounding Separately Derived Alternating-Current Systems.
  • 250.30(A)(4)&(5) Grounding Separately Derived Alternating-Current Systems.
  • 250.30(A)(6)(a) Grounding Electrode Conductor, Multiple Separately Derived Systems.
  • 250.52 Electrodes Permitted for Grounding.
  • 250.52(A)(2) Metal In-ground Support Structure(s).
  • 250.52(B) Not Permitted for Use as Grounding Electrodes.
  • 250.53(C) Bonding Jumper.
  • 250.64(A) Aluminum or Copper-Clad Aluminum Conductors.
  • 250.64(B) Securing and Protection Against Physical Damage.
  • 250.64(B) Exposed to Physical Damage.
  • 250.64(D)(1)(3) Building or Structure with Multiple Disconnecting Means in Separate Enclosures. Common Grounding Electrode Conductor and Taps.
  • 250.64(E) Raceways, Cable Armor, and Enclosures for Grounding Electrode Conductors.
  • 250.66(A) Size of Alternating-Current Grounding Electrode Conductor.
  • Table 250.66 Grounding Electrode Conductor for Alternating-Current Systems.
  • 250.68(C)(1) Grounding Electrode Conductor Connections. Interior Metal Water Piping.
  • 250.68(C)(2) Grounding Electrode Conductor Connections. Metal Structural Frame of a Building.
  • 250.68(C)(3) Grounding Electrode Conductor Connections.
  • 250.70 Methods of Grounding and Bonding Conductor Connection to Electrodes.
  • 250.80 Service Raceways and Enclosures.
  • 250.86 Other Conductor Enclosures and Raceways.
  • 250.94 Bonding for Communications Systems.
  • 250.102(A) Grounded Conductor, Bonding Conductors, and Jumpers.
  • Table 250.102(C)(1). Grounded Conductor, Main Bonding Jumper, System Bonding Jumper, and Supply-Side Bonding Jumper for Alternating-Current Systems.
  • 250.104(A) Metal Water Piping.
  • 250.104(B) Bonding of Piping Systems and Exposed Structural Metal. Other Metal Piping.
  • 250.109 Metal Enclosures.
  • 250.118(A)(5)(e) Types of Equipment Grounding Conductors.
  • 250.118(B) Uses Not Permitted for Equipment Grounding Conductors.
  • 250.119 Identification of Wire-Type Equipment Grounding Conductors.
  • NEC Table 250.122.
  • 250.122(F) Size of Equipment Grounding Conductors in Parallel.
  • 250.130(C) Replacement of Nongrounding Receptacle or Snap Switch and Branch Circuit Extensions.
  • 250.148 Continuity of Equipment Grounding Conductors and Attachment in Boxes.
  • 250.166 Size of the Direct-Current Grounding Electrode Conductor.
  • 250.186 Grounding Service-Supplied Alternating Current Systems.
  • 440.9 Grounding and Bonding.
  • 680.7(C) Grounding and Bonding Terminals.
  • 680.26(B)(2) Perimeter Surfaces.
  • Types of Circuits.
  • Watts, Volts, Ohms.
  • Resistance.
  • Article 100 Definitions. Show Windows.
  • 110.9 Interrupting Rating.
  • 210.19(A)(1) Conductors - Minimum Ampacity and Size.
  • 215.2(A) Feeders. Minimum Rating and Size.
  • 220.5 Calculations.
  • 314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
  • 314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
  • 314.28 Pull and Junction Boxes and Conduit Bodies. Straight Pulls.
  • 314.28 Pull and Junction Boxes and Conduit Bodies. Angle Pulls, U Pulls and Splices.
  • 314.28 Pull and Junction Boxes and Conduit Bodies. Angle Pulls, U Pulls and Splices.
  • Angle Pulls, U Pulls and Splices & Table 312.6(A).
  • Ampacity Table 310.16.
  • Ampacity Table 310.16.
  • 310.15(C)(1) Adjustment Factors for More Than Three Current-Carrying Conductors.
  • 310.15(B)(2) Raceways and Cables Exposed to Sunlight on Rooftops.
  • 409.22 Short-Circuit Current Rating.
  • 430.6 Ampacity and Motor Rating Determination.
  • 430.22 Motor Branch Circuits.
  • 430.24 Several Motors or a Motor(s) and Other Load(s).
  • 430.52 Motor Branch-Circuit Short-Circuit and Ground-Fault Protection.
  • 430.28 Motor Feeder Taps. 10 Foot Tap Rule.
  • 430.28 Motor Feeder Taps. 25 Foot Tap Rule.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other FL Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
Electrical Safety Banner
Electrical Safety
Course #: 0802072
Credit Type: Safety (S)
Credit Hours: 1.0
Price: $35
 
False Alarm Prevention Banner
False Alarm Prevention
Course #: 802971
Credit Type: False Alarm
Credit Hours: 2.0
Price: $50
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Course #: 802993
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75
 
Boxes and Enclosures (Webinar) Banner
Boxes and Enclosures (Webinar)
Course #: 802997
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Course #: 802996
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Course #: 0802994
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75
 
Grounding & NEC Fundamentals Banner
Grounding & NEC Fundamentals
Course #: 0803212
Credit Type: Technical (T)
Credit Hours: 6.0
Price: $69
 
Passing the Electrical Inspection (Webinar) Banner
Passing the Electrical Inspection (Webinar)
Course #: 802995
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75
 
2023 NEC Code Changes Update Banner
2023 NEC Code Changes Update
Course #: 0802761
Credit Type: Technical (T)
Credit Hours: 6.0
Price: $69
 
Advanced Available Fault Current Banner
Advanced Available Fault Current
Course #: 0802069
Credit Type: Advanced (ADV)
Credit Hours: 1.0
Price: $35
 
Florida Business Practices Banner
Florida Business Practices
Course #: 0802074
Credit Type: Business (B)
Credit Hours: 1.0
Price: $35
 
Florida Laws and Rules Banner
Florida Laws and Rules
Course #: 0802073
Credit Type: Laws/Rules (LR)
Credit Hours: 1.0
Price: $35
 
Florida Workers Compensation Rules Banner
Florida Workers Compensation Rules
Course #: 0802071
Credit Type: Workers Comp (C)
Credit Hours: 1.0
Price: $35
 
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Course #: 0802381
Credit Type: Technical (T)
Credit Hours: 6.0
Price: $69
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Course #: 803003
Credit Type: Technical (T)
Credit Hours: 4.0
Price: $75