This Arkansas Electrical Continuing Education License Renewal Course reviews the top 75 most important National Electrical Code changes from the 2023 NEC. Covers code changes starting from the Article 90 through the last in Chapter 9. This one course is enough to renew your AR electrical license. Earns 8 hours of Electrical Continuing Education for Electrical License Renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 NEC Code Changes Update Course Topics:
  • 90.5(C) Explanatory Material.
  • Article 100.
  • Article 100 Definitions. Accessible (as applied to wiring methods).
  • Article 100 Definitions. Likely to Become Energized.
  • Article 100 Definitions. Work Surface.
  • 110.3(B) Installation and Use.
  • 110.16(B) Service Equipment and Feeder Supplied Equipment.
  • 110.22(A) Identification of Disconnecting Means.
  • 110.26(A)(4) Limited Access.
  • 110.26(A)(6) Grade, Floor, or Working Platform.
  • 110.26(E) Dedicated Equipment Space.
  • 200.6 Means of Identifying Grounded Conductors.
  • Article 210.
  • 210.4 Multiwire Branch Circuits.
  • 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  • 210.8(A) GFCI Protection for Dwelling Units.
  • 210.8(B) GFCI Protection for Other Than Dwelling Units.
  • 210.8(D) GFCI Protection for Specific Appliances.
  • 210.8(F) GFCI Protection for Outdoor Outlets.
  • 210.12 AFCI Protection.
  • 210.18 Branch Circuit Rating.
  • 210.19 Conductors - Minimum Ampacity and Size.
  • 210.52(A)(2) Wall Space for Dwelling Unit Receptacle Outlets.
  • 210.52(C) Dwelling Unit Receptacle Outlets at Countertops and Work Surfaces.
  • 210.52(C)(2) & (3) Island and Peninsular Countertops and Work Surfaces.
  • 225.41 Emergency Disconnects.
  • 230.7 Other Conductors.
  • 230.71(B) Two to Six Service Disconnecting Means.
  • 240.4(B) Overcurrent Devices Rated 800 Amperes or Less.
  • 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers.
  • 240.11 Selective Coordination.
  • 240.89 Replacement Trip Units.
  • Article 245 Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 Volts dc.
  • 250.64(G) Enclosures with Ventilation Openings.
  • 250.68(C) Grounding Electrode Conductor Connections.
  • 250.102(C)(2) Size of SSBJ for Parallel Conductor Installations.
  • 250.140 Frames of Ranges and Clothes Dryers.
  • Table 300.5 Minimum Cover Requirements.
  • 300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
  • 312.8(A) Splices, Taps, and Feed-Through Conductors.
  • 314.24(C) Clearances for Side-Wiring Entrances.
  • 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible.
  • 334.10(2) Uses Permitted.
  • 334.15(B) Protection from Physical Damage.
  • 334.19 NM Cable Entries.
  • 334.24 Bending Radius.
  • 344.28 Reaming and Threading.
  • 352.44 Expansion Fittings and Earth Movement.
  • 358.10 Uses Permitted.
  • 404.30 Switch Enclosures with Doors.
  • 406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  • 406.4(G) Protection of Floor Receptacles.
  • 406.9(A) & (B) Receptacles in Damp or Wet Locations.
  • 406.9(C) Bathtub and Shower Space.
  • 406.12 Tamper-Resistant Receptacles.
  • 408.4(B) Source of Supply.
  • 408.9 Replacement Panelboards.
  • 410.10(D) Bathtub and Shower Areas.
  • 410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  • 440.11 General.
  • 440.14 Location.
  • 445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  • 680.5 GFCI and SPGFCI Protection.
  • 680.21(D) Pool Pump Motor Replacement.
  • 680.54(C) Equipotential Bonding of Splash Pads.
  • Figure 690.1.
  • 690.4(G) PV Equipment Floating on Bodies of Water.
  • 690.12 Rapid Shutdown of PV Systems on Buildings.
  • 700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  • 700.27 Class 2 Powered Emergency Lighting Systems.
  • 700.32 Selective Coordination.
  • 705.11(B), (C), and (F) Conductors and Connections.
  • 725.1 Scope.
  • 725.24 Mechanical Execution of Work.
  • Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other AR Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2026 NEC Code Changes Update Banner
2026 NEC Code Changes Update
Course #: E2025-41
Credit Type: NEC Update
Credit Hours: 8.0
Price: $89
 
2023 NEC Code Changes Update Banner
2023 NEC Code Changes Update
Course #: E2318
Credit Type: NEC Update
Credit Hours: 8.0
Price: $89