2023 NEC Code Changes Update

Approved by the Alabama Board of Electrical Contractors for Alabama Electricians License Renewal.

Yes! We Are Approved by the Alabama Board of Electrical Contractors for Alabama Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 NEC Code Changes Update14.0 NEC Update N/A 3/6/2023
-through-
3/6/2027
$125
-26

$99
This Alabama Electrical Continuing Education License Renewal Course reviews the top 125 most important National Electrical Code changes from the 2023 NEC. Covers code changes starting from Article 90 through Chapter 9. This one course is enough to renew your AL electrical license. Earns 14 hours of Electrical Continuing Education for Electrical License Renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 NEC Code Changes Update Course Topics:
  • 90.5(C) Explanatory Material.
  • Article 100.
  • Article 100 Definitions. Accessible (as applied to wiring methods).
  • Article 100 Definitions. Counter (Countertop).
  • Article 100 Definitions. Likely to Become Energized.
  • Article 100 Definitions. Work Surface.
  • 110.3(A)(8) Cybersecurity.
  • 110.3(B) Installation and Use.
  • 110.16(B) Service Equipment and Feeder Supplied Equipment.
  • 110.22(A) Identification of Disconnecting Means.
  • 110.26(A)(4) Limited Access.
  • 110.26(A)(6) Grade, Floor, or Working Platform.
  • 110.26(C)(2) Large Equipment.
  • 110.26(C)(3) Personnel Doors.
  • 110.26(E) Dedicated Equipment Space.
  • 110.29 In Sight From.
  • 200.6 Means of Identifying Grounded Conductors.
  • Article 210.
  • 210.4 Multiwire Branch Circuits.
  • 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  • 210.8(A) GFCI Protection for Dwelling Units.
  • 210.8(B) GFCI Protection for Other Than Dwelling Units.
  • 210.8(D) GFCI Protection for Specific Appliances.
  • 210.8(F) GFCI Protection for Outdoor Outlets.
  • 210.12 AFCI Protection.
  • 210.18 Branch Circuit Rating.
  • 210.19 Conductors - Minimum Ampacity and Size.
  • 210.52(A)(2) Wall Space for Dwelling Unit Receptacle Outlets.
  • 210.52(C) Dwelling Unit Receptacle Outlets at Countertops and Work Surfaces.
  • 210.52(C)(2) & (3) Island and Peninsular Countertops and Work Surfaces.
  • 225.41 Emergency Disconnects.
  • 230.7 Other Conductors.
  • 230.30(B) & 230.43 Wiring Methods for Service Conductors.
  • 230.67 Surge Protection.
  • 230.71(B) Two to Six Service Disconnecting Means.
  • 240.2 Reconditioned Equipment.
  • 240.4(B) Overcurrent Devices Rated 800 Amperes or Less.
  • 240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers.
  • 240.11 Selective Coordination.
  • 240.60(E) Fuse Reducers.
  • 240.89 Replacement Trip Units.
  • Article 245 Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 Volts dc.
  • 250.64(G) Enclosures with Ventilation Openings.
  • 250.68(C) Grounding Electrode Conductor Connections.
  • 250.102(C)(2) Size of SSBJ for Parallel Conductor Installations.
  • 250.118 Types of Equipment Grounding Conductors.
  • 250.130 Equipment Grounding Conductor Connections.
  • 250.140 Frames of Ranges and Clothes Dryers.
  • 300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
  • 300.4(G) Fittings.
  • Table 300.5 Minimum Cover Requirements.
  • 300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
  • Article 305 General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 Volts ac, 1500 Volts dc, Nominal.
  • 310.15(B)(2) Rooftop.
  • 312.8(A) Splices, Taps, and Feed-Through Conductors.
  • 312.10 Screws or Other Fasteners.
  • 312.102 Doors or Covers.
  • 314.5 Screws or Other Fasteners.
  • 314.16(B)(6) Terminal Block Fill.
  • 314.23(H)(1) Pendant Boxes.
  • 314.24(B)(4) Conductors 12 or 10 AWG.
  • 314.24(C) Clearances for Side-Wiring Entrances.
  • 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible.
  • Article 315 Medium Voltage Conductors, Cable, Cable Joints, and Cable Terminations.
  • 320.23(A) Cables Run Across the Top of Framing Members.
  • 334.10(2) Uses Permitted.
  • 334.15(B) Protection from Physical Damage.
  • 334.19 NM Cable Entries.
  • 334.24 Bending Radius.
  • 344.28 Reaming and Threading.
  • 352.44 Expansion Fittings and Earth Movement.
  • 358.10 Uses Permitted.
  • Article 369 Insulated Bus Pipe IBP/ Tubular Covered Conductors (TCC) Systems.
  • Article 371 Flexible Bus Systems.
  • Article 400 Part IV. Portable Power Feeder Cables Over 2000 Volts, Nominal.
  • 404.30 Switch Enclosures with Doors.
  • 406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  • 406.4(G) Protection of Floor Receptacles.
  • 406.6(D) Receptacle Faceplates with Integral Night Light and/or USB Charger.
  • 406.9(A) & (B) Receptacles in Damp or Wet Locations.
  • 406.9(C) Bathtub and Shower Space.
  • 406.12 Tamper-Resistant Receptacles.
  • 408.4(A) Circuit Directory or Circuit Description.
  • 408.4(B) Source of Supply.
  • 408.9 Replacement Panelboards.
  • 408.38 Enclosure.
  • 410.10(D) Bathtub and Shower Areas.
  • 410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  • 410.184 GFCI Protection and SPGFCI Protection.
  • Article 410 Part XVII Special Provisions for Ultraviolet Germicidal Irradiation Luminaires.
  • 422.18 Ceiling-Suspended (Paddle) Fans.
  • 440.8 Single Machine and Location.
  • 440.11 General.
  • 440.14 Location.
  • 445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  • 500.4 Documentation.
  • 500.7 Protection Techniques.
  • 511.7 Fixed Wiring Above Class I Locations.
  • Article 512 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials.
  • 550.32 Service Equipment.
  • 555.15 Replacement of Equipment.
  • 555.35 Ground-Fault Protection of Equipment (GFPE) and Ground-Fault Circuit-Interrupter.
  • 625.40 Electric Vehicle Branch Circuit.
  • 680.5 GFCI and SPGFCI Protection.
  • 680.12 Equipment Rooms, Vaults, and Pits.
  • 680.21(D) Pool Pump Motor Replacement.
  • 680.54(C) Equipotential Bonding of Splash Pads.
  • Figure 690.1.
  • 690.4(G) PV Equipment Floating on Bodies of Water.
  • 690.12 Rapid Shutdown of PV Systems on Buildings.
  • 690.15(D) Equipment Disconnecting Means.
  • 690.31(B) Identification and Grouping.
  • 695.6(D) Fire Pump Wiring.
  • 700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  • 700.12(H) Battery-Equipped Emergency Luminaires.
  • 700.27 Class 2 Powered Emergency Lighting Systems.
  • 700.32 Selective Coordination.
  • 705.11(A) Service Connections.
  • 705.11(B), (C), and (F) Conductors and Connections.
  • Article 722 Cables for Power-Limited Circuits and Fault-Managed Power Circuits.
  • Article 724 Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits.
  • 725.1 Scope.
  • 725.24 Mechanical Execution of Work.
  • 760.33 Supply-Side Overvoltage Protection.
  • Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other AL Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2026 NEC Code Changes Update Banner
2026 NEC Code Changes Update
Credit Type: NEC Update
Credit Hours: 14.0
Price: $125
 
2023 NEC Code Changes Update Banner
2023 NEC Code Changes Update
Credit Type: NEC Update
Credit Hours: 14.0
Price: $125
 
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Credit Type: NEC Update
Credit Hours: 14.0
Price: $125