Available Fault Current

Approved by the International Code Council for International Code Council ICC Inspectors Certification Renewal.

Yes! We Are Approved by the International Code Council for International Code Council ICC Inspectors' Certification Renewal.

International Code Council ICC Inspector Board Continuing Education Provider License#: 2192
ICC Inspector Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
Available Fault Current4.0 ICC PPP 39807 2/7/2024
-through-
1/4/2027
$59
This online/on demand 4 Hour ICC Preferred Provider Electrical Continuing Education Course takes the difficult topics of available fault current, short circuit current ratings, fully rated and series rated electrical systems and places them in an easy to understand format. This course will earn you 4 hours (.4 CEUs) towards your ICC inspector credential renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Available Fault Current Course Topics:
  Available Fault Current.
  Available Fault Current and Characteristics of the Circuit.
  Available Fault Current. Understanding the Calculations.
  Available Fault Current. Example Calculation.
  Article 100 Definitions. Interrupting Rating.
  Article 100 Definitions. Short Circuit Current Rating.
  110.9 Interrupting Rating of Defensive and Passive Devices.
  110.9 Interrupting Rating.
  240.83(C) Circuit Breaker Marking. Interrupting Rating.
  110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  Available Fault Current. Applying It Downstream of the Service.
  110.16(A) Arc-Flash Hazard Warning. General.
  110.16(B) Arc-Flash Hazard Warning. Service Equipment.
  110.24(A) Available Fault Current. Field Marking.
  110.24(B) Available Fault Current. Modifications.
  Available Fault Current and Remodel or Service Work.
  Available Fault Current and Blueprints.
  Available Fault Current on the Plans. Exercise 1.
  Available Fault Current on the Plans. Exercise 2.
  Available Fault Current on the Plans. Exercise 3.
  Available Fault Current on the Plans. Exercise 4.
  Fully Rated Systems.
  Series Rated Systems.
  240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  110.22(B) Engineered Series Combination Systems.
  240.86(B) Series Rated Systems. Tested Combinations.
  110.22(C) Tested Series Combination Systems.
  Verifying a Tested Series Rated Combination. Circuit Breakers.
  Verifying a Tested Series Rated Combination. Fuses.
  NEC 110.3(B) and The Intermixing of Circuit breakers.
  240.86(C) Series Ratings. Motor Contribution Exercise 1.
  240.86(C) Series Ratings. Motor Contribution Exercise 2.
  Series Ratings and Selective Coordination.
  Circuit Breakers Protecting Circuit Breakers.
  Fuses Protecting Circuit Breakers.
  Fuse Protection of Passive Components.
  Selecting a Fuse Because of its Current Limiting Characteristics.
  Short-Circuit Current Ratings Dependent on Specific OCPDs.
  230.82(3) Equipment Connected to the Supply Side of Service Disconnect.
  Surge-Protective Devices. Short-Circuit Current Rating.
  Article 100 & 409.22 Industrial Control Panels.
  409.110 Industrial Control Panels. Marking.
  430.8 Marking on Motor Controllers.
  430.99 Motor Control Centers. Available Fault Current.
  440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  480.7 DC Disconnect Methods. Maximum Available Short-Circuit Current.
  620.16 Elevators. Short-Circuit Current Rating.
  700.5(E) Emergency System Transfer Equipment. Documentation.
  701.4 Legally Required Standby Systems. Capacity and Rating.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other ICC s took these icc continuing education courses with us:
Click on a banner below to go to the page for that course
2023 NEC Code Changes Update Part 1 Banner
2023 NEC Code Changes Update Part 1
Course #: 39802
Credit Type: ICC PPP
Credit Hours: 8.0
Price: $139
 
Passing the Electrical Inspection Banner
Passing the Electrical Inspection
Course #: 39520
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $59
 
Available Fault Current Banner
Available Fault Current
Course #: 39807
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $59
 
Grounding and Bonding Banner
Grounding and Bonding
Course #: 39804
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $59
 
2023 NEC Code Changes Update Part 2 Banner
2023 NEC Code Changes Update Part 2
Course #: 39803
Credit Type: ICC PPP
Credit Hours: 8.0
Price: $139
 
Electrical Theory and Calculations Banner
Electrical Theory and Calculations
Course #: 39806
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $59
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Course #: 42387
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75
 
Boxes and Enclosures (Webinar) Banner
Boxes and Enclosures (Webinar)
Course #: 42389
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Course #: 42385
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75
 
Passing the Electrical Inspection (Webinar) Banner
Passing the Electrical Inspection (Webinar)
Course #: 42388
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Course #: 42390
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Course #: 43945
Credit Type: ICC PPP
Credit Hours: 4.0
Price: $75