NEC 2020 Code Changes Update Arkansas Electrical Continuing Education Course

NEC 2020 Code Changes Update

Approved by the Arkansas Board of Electrical Examiners for Arkansas Electricians License Renewal.

Yes! We Are Approved by the Arkansas Board of Electrical Examiners for Arkansas Electricians' License Renewal.

Electrical Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2020 Code Changes Update8.0 NEC Update 1611 2/24/2021
-through-
5/24/2024
$89
-20

$69
This Arkansas Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2020 NEC. Covers code changes starting from the first in Article 100 through the last in Chapter 7. This one course is enough to renew your AR electrical license. Earns 8 hours of Electrical Continuing Education for Electrical License Renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2020 Code Changes Update Course Topics:
  Article 100 Accessible as Applied to Equipment.
  Article 100 Fault Current & Available Fault Current.
  Article 100 Free Air (as applied to conductors).
  110.12(C) Mechanical Execution of Work. Cables and Conductors.
  110.21(A)(2) Reconditioned Equipment.
  110.22(A) Identification of Disconnecting Means. General.
  110.24(A) Field Marking.
  110.26(C)(2) Large Equipment.
  210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  210.8(A) GFCI Protection. Dwelling Units.
  210.8(B) GFCI Protection. Other Than Dwelling Units.
  210.8(D) GFCI Protection for Specific Appliances.
  210.8(E) Equipment Requiring Servicing.
  210.8(F) GFCI Protection. Outdoor Outlets.
  210.11(C)(3) Bathroom Branch Circuits.
  210.11(C)(4) Garage Branch Circuits.
  210.12(C) AFCI Protection in Guest Rooms, Guest Suites, and Patient Sleeping Rooms in Nursing Homes and Limited-Care Facilities.
  210.12(D) AFCI Protection. Branch Circuit Extensions or Modifications in Dwelling Units, Dormitory Units, Guest Rooms and Guest Suites.
  210.19(A)(1) Branch Circuits.
  210.52(B)(1) Receptacle Outlets Served.
  210.52(C) Countertops and Work Surfaces.
  210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  210.63 Equipment Requiring Servicing.
  210.70(C) Lighting Outlets Required. All Occupancies.
  215.9 Ground-Fault Circuit-Interrupter Protection for Personnel.
  225.10 Wiring on Buildings (or Other Structures).
  230.46 Spliced and Tapped Conductors.
  230.62 Service Equipment Barriers.
  230.66 Marking.
  230.67 Surge Protection.
  230.71 Maximum Number of Disconnects.
  230.75 Disconnection of Grounded Conductor.
  230.85 Emergency Disconnects.
  240.6 Restricted Access Adjustable-Trip Circuit Breakers.
  240.21 Feeder Taps.
  240.24(A) Accessibility.
  240.33 Vertical Position.
  240.62 Reconditioned Equipment.
  240.67 Arc Energy Reduction.
  240.86 Series Ratings and Motor Contribution.
  240.87(A) & (B) Arc Energy Reduction. Documentation and Method to Reduce Clearing Time.
  250.25 Grounding Systems Permitted to Be Connected on the Supply Side of the Disconnect.
  250.64(A) Aluminum or Copper-Clad Aluminum Conductors.
  250.64(B) Exposed to Physical Damage.
  250.104(A) Metal Water Piping.
  310.12 Single-Phase Dwelling Services and Feeders.
  310.15(B) Ambient Temperature Correction Factors.
  310.16 Ampacity Table.
  314.16(B)(5) Equipment Grounding Conductor Fill.
  314.27(C) Boxes at Ceiling-Suspended (Paddle) Fan Outlets.
  330.130 Hazardous (Classified) Locations.
  334.104 Conductors.
  338.10(B)(4) Installation Methods for Branch Circuits and Feeders.
  406.12 Tamper-Resistant Receptacles.
  406.13 Single-Pole Separable-Connector Type.
  408.6 Short-Circuit Current Rating.
  408.8 Reconditioning of Equipment.
  408.18(C) Connections.
  408.43 Panelboard Orientation.
  410.69 Identification of Control Conductor Insulation.
  410.118 Access to Other Boxes.
  410 Part XVI. Special Provisions for Horticultural Lighting Equipment.
  410.176 Locations Not Permitted.
  422.5 Ground-Fault Circuit-Interrupter (GFCI) Protection for Personnel.
  518.6 Illumination.
  590.4(G) Splices.
  590.8 Overcurrent Protective Devices.
  680.4 Inspections After Installation.
  680.21(C) & 680.21(D) GFCI Protection.
  690.12(B)(2) Rapid Shutdown. Inside the Array Boundary.
  690.31(D) Direct-Current Circuits on or in Buildings.
  700.12(I)(2) Installation of Unit Equipment.
  700.16 Emergency Illumination.
  705.12 Load-Side Source Connections.
  725.144(B) Use of Class 2-LP or Class 3-LP Cables to Transmit Power and Data.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other AR Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Course #: 1611
Credit Type: NEC Update
Credit Hours: 8.0
Price: $89
 
2023 NEC Code Changes Update Banner
2023 NEC Code Changes Update
Course #: E2318
Credit Type: NEC Update
Credit Hours: 8.0
Price: $89