Oregon Electrical Rules and Laws (ORL/OESC) 2026

Approved by the Oregon Building Codes Division - Electrical Board for Oregon Electricians License Renewal.

Yes! We Are Approved by the Oregon Building Codes Division - Electrical Board for Oregon Electricians' License Renewal. Oregon courses CAN be reciprocated to the state of Washington.

THIS YEAR THERE IS NO TIMER ON OUR COURSES! That is right, now you can finish as fast as you are smart. The way it should be, if you are smart, you finish faster!
Oregon Electrical Board Continuing Education Provider License#: BCD CE-71
Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
Oregon Electrical Rules and Laws (ORL/OESC) 20264.0 Rules and Laws 9401896 11/19/2026
-through-
10/1/2029
$50
This 4 Hour Oregon Electrical Continuing Education License Renewal Course will cover the updated Oregon Electrical Specialty Code and Oregon Rules and Laws. This course meets the minimum code-change requirements for the license types set forth in the board's license matrix. This course will earn you 4 hours of electrical continuing education of credit type "Rules and Laws (ORL)" for your electrical license renewal in Oregon.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Oregon Electrical Rules and Laws (ORL/OESC) 2026 Course Topics:
  • Introduction to OESC Table 1-E. Process to Find Code Changes and OESC 90.4.
  • OESC 90.4(D) New Products, Constructions, or Materials.
  • OESC Article 100 Definitions. Critical Operations Data System.
  • OESC 100 Definitions. Fire Protection System.
  • OESC 110.26(D) Illumination.
  • OESC 210.8 GFCI Protection.
  • OESC 210.8(A) Exception 2.
  • OESC 210.8(A) Exceptions to GFCI Protection.
  • OESC 210.12(B) Arc-Fault Circuit-Interrupter Protection.
  • OESC 210.12(C) Arc-Fault Circuit-Interrupter Protection. Dormitory Units.
  • OESC 210.12(E) Branch Circuit Wiring Extensions, Modifications or Replacements.
  • OESC 210.52(E)(3) Balconies, Decks, and Porches.
  • OESC 210.52(J) Alcoves.
  • OESC 210.63 Heating, Air Conditioning, and Refrigeration Equipment Outlet.
  • OESC 210.65 Meeting Rooms.
  • OESC 230.95(E) Performance Testing.
  • OESC 250.94 Bonding for Other Systems.
  • OESC 250.120(A) Raceways, Cable Trays, Cable Armor, Cablebus, or Cable Sheaths.
  • OESC 300.7(G) Raceway Seals.
  • OESC 330.30 Securing and Supporting.
  • OESC 334.12 Uses Not Permitted.
  • OESC 334.15(C) In Unfinished Basements.
  • OESC 336.10 Uses Permitted.
  • OESC 400.12 Uses Not Permitted.
  • OESC 406.12 Replacements.
  • OESC 408.3(A) Reconditioned Equipment Permitted.
  • OESC 445.2 Listing.
  • OESC 517.10 Applicability.
  • OESC 547.28 Receptacles.
  • OESC 590.9 Overcurrent Protective Devices.
  • OESC 620.6 Working Clearances.
  • OESC 620.37 Wiring in Hoistways, Machine Rooms, Control Rooms, Machinery Spaces, and Control Spaces.
  • OESC 620.51 Disconnecting Means.
  • OESC 690.12 Rapid Shutdown of PV Systems on Buildings.
  • OESC 690.47 Grounding Electrode System.
  • OESC Article 700 Emergency Systems.
  • OESC 700.32 Selective Coordination.
  • OESC 702.4 Capacity and Rating.
  • OESC 720.30(A)(3) Mechanical Execution of Work.
  • Permit Requirements and Exemptions.
  • Phased Permitting.
  • Permit Fee Structure.
  • Temporary Services.
  • Miscellaneous Permit Fees.
  • Scope of Work Allowed Under Specific Licenses.
  • Clarification of Electrical Licensing.
  • Electrical Licensing Exemptions.
  • Electrical Licensing Clarifications. Supervising Electricians.
  • Electrical Licensing Clarifications. Journeyman and Limited Licenses.
  • Statewide Code Interpretations.
  • Explanation of Statewide Alternate Methods.
  • Appeals Process. Alternative Appeal Procedure.
  • Appeals Process. State Building Code Appeal Process. Exercise 1.
  • Appeals Process. State Building Code Appeal Process. Exercise 2.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other OR Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2026 NEC Code Changes Update Part 1 Banner
2026 NEC Code Changes Update Part 1
Course #: 9401936
Credit Type: Code Change
Credit Hours: 8.0
Price: $75
 
2026 NEC Code Changes Update Part 2 Banner
2026 NEC Code Changes Update Part 2
Course #: 9401946
Credit Type: Code Change
Credit Hours: 8.0
Price: $75
 
NEC 2026 Code Changes Update - 12 Hours Banner
NEC 2026 Code Changes Update - 12 Hours
Course #: 9401966
Credit Type: Code Change
Credit Hours: 12.0
Price: $100
 
NEC 2026 Code Changes Update - 4 Hours Banner
NEC 2026 Code Changes Update - 4 Hours
Course #: 9401956
Credit Type: Code Change
Credit Hours: 4.0
Price: $50
 
Oregon Electrical Rules and Laws (ORL/OESC) 2026 Banner
Oregon Electrical Rules and Laws (ORL/OESC) 2026
Course #: 9401896
Credit Type: Rules and Laws
Credit Hours: 4.0
Price: $50
 
2026 NEC Grounding and Bonding Banner
2026 NEC Grounding and Bonding
Course #: 9401906
Credit Type: Code Related
Credit Hours: 4.0
Price: $50
 
2026 Available Fault Current Banner
2026 Available Fault Current
Course #: 9401886
Credit Type: Code Related
Credit Hours: 4.0
Price: $50
 
2026 Theory and Calculations Banner
2026 Theory and Calculations
Course #: 9401916
Credit Type: Code Related
Credit Hours: 4.0
Price: $50
 
Passing the Inspection Banner
Passing the Inspection
Course #: 9401926
Credit Type: Code Related
Credit Hours: 4.0
Price: $50