Electrical Engineer Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 NEC Code Changes Update part 215.0 NEC N/A 5/29/2024
-through-
6/3/2027
$65
This Tennessee Electrical Engineer Continuing Education License renewal course reviews 100 of the most important 2023 National Electrical Code changes picking up in from Article 334 and continuing through Chapter 9.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 NEC Code Changes Update part 2 Course Topics:
  334.10(2) Uses Permitted.
  334.15(B) Protection from Physical Damage.
  334.19 NM Cable Entries.
  334.24 Bending Radius.
  344.28 Reaming and Threading.
  352.44 Expansion Fittings and Earth Movement.
  358.10 Uses Permitted.
  Article 369 Insulated Bus Pipe IBP/ Tubular Covered Conductors (TCC) Systems.
  Article 371 Flexible Bus Systems.
  Article 400 Part IV. Portable Power Feeder Cables Over 2000 Volts, Nominal.
  404.16 Reconditioned Equipment.
  404.30 Switch Enclosures with Doors.
  406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  406.4(G) Protection of Floor Receptacles.
  406.6(D) Receptacle Faceplates with Integral Night Light and/or USB Charger.
  406.9(A) & (B) Receptacles in Damp or Wet Locations.
  406.9(C) Bathtub and Shower Space.
  406.12 Tamper-Resistant Receptacles.
  408.2 Reconditioned Equipment.
  408.4(A) Circuit Directory or Circuit Description.
  408.4(B) Source of Supply.
  408.9 Replacement Panelboards.
  408.38 Enclosure.
  408.43 Panelboard Orientation.
  410.2 Reconditioned Equipment.
  410.10(D) Bathtub and Shower Areas.
  410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  410.184 GFCI Protection and SPGFCI Protection.
  Article 410 Part XVII Special Provisions for Ultraviolet Germicidal Irradiation Luminaires.
  422.18 Ceiling-Suspended (Paddle) Fans.
  424.48 Installation of Cables in Walls.
  430.2 Reconditioned Motors.
  430.52 Rating or Setting for Individual Motor Circuit.
  440.8 Single Machine and Location.
  440.11 General.
  440.14 Location.
  445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  Articles 490 & 495.
  500.4 Documentation.
  500.7 Protection Techniques.
  511.7 Fixed Wiring Above Class I Locations.
  Article 512 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials.
  517.6 Patient Care - Related Electrical Equipment.
  517.10(B) Areas Not Covered by Part II of Article 517.
  517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces.
  517.14 Panelboard Bonding.
  517.22 Demand Factors.
  518.4(B) Communications, Signaling Systems, Data Systems, Fire Alarm Systems, and Systems Less Than 120 Volts, Nominal.
  547.26 Physical Protection.
  550.32 Service Equipment.
  555.4 Location of Service Equipment.
  555.14 Equipotential Planes and Bonding of Equipotential Planes.
  555.15 Replacement of Equipment.
  555.35 Ground-Fault Protection of Equipment (GFPE) and Ground-Fault Circuit-Interrupter.
  555.36 Disconnecting Means for Shore Power Connection(s).
  625.40 Electric Vehicle Branch Circuit.
  625.42 Rating.
  625.49 Power for Systems Operating in Island Mode.
  630.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  680.5 GFCI and SPGFCI Protection.
  680.12 Equipment Rooms, Vaults, and Pits.
  680.14 Corrosive Environments.
  680.21(D) Pool Pump Motor Replacement.
  680.54(C) Equipotential Bonding of Splash Pads.
  Figure 690.1.
  690.2 Deletion of PV Output Circuit.
  690.4(F) Electronic Power Converters Mounted in Not Readily Accessible Locations.
  690.4(G) PV Equipment Floating on Bodies of Water.
  690.7 Maximum Voltage.
  690.8(A) Calculation of Maximum Circuit Current.
  690.8(D) Multiple PV String Circuits.
  690.12 Rapid Shutdown of PV Systems on Buildings.
  690.12(A) Controlled Conductors and Rapid Shutdown.
  690.12(B) Controlled Limits.
  690.12(D) Buildings with Rapid Shutdown.
  690.15(D) Equipment Disconnecting Means.
  690.31(B) Identification and Grouping.
  690.31(C)(2) Cable Tray.
  690.31(G) Over 1000 Volts DC.
  690.43(C) Equipment Grounding Conductor Location.
  695.6(D) Fire Pump Wiring.
  700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  700.12(H) Battery-Equipped Emergency Luminaires.
  700.27 Class 2 Powered Emergency Lighting Systems.
  700.32 Selective Coordination.
  705.10 Identification of Power Sources.
  705.11(A) Service Connections.
  705.11(B), (C), and (F) Conductors and Connections.
  705.11(D) and (E) Service Disconnecting Means, Bonding and Grounding.
  705.12(A) Feeders.
  705.12(A) Feeder Taps.
  706.15 Disconnecting Means.
  Article 722 Cables for Power-Limited Circuits and Fault-Managed Power Circuits.
  Article 724 Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits.
  725.1 Scope.
  725.24 Mechanical Execution of Work.
  Article 726 Class 4 Fault-Managed Power Systems.
  760.33 Supply-Side Overvoltage Protection.
  800.24 Mechanical Execution of Work.
  Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other TN s took these engineer continuing education courses with us:
Click on a banner below to go to the page for that course
2023 NEC Code Changes Update part 1 Banner
2023 NEC Code Changes Update part 1
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
2023 NEC Code Changes Update part 2 Banner
2023 NEC Code Changes Update part 2
Credit Type: NEC
Credit Hours: 15.0
Price: $65
 
Available Fault Current Banner
Available Fault Current
Credit Type: NEC
Credit Hours: 4.0
Price: $50
 
Ethics in Engineering Banner
Ethics in Engineering
Credit Type: Ethics
Credit Hours: 2.0
Price: $25
 
Passing the Inspection Banner
Passing the Inspection
Credit Type: NEC
Credit Hours: 4.0
Price: $50