NEC 2023 Code Changes Update Part 2

Approved by the Alaska Division of Corporations, Business and Professional Licensing for Alaska Electricians License Renewal.

Yes! We Are Approved by the Alaska Division of Corporations, Business and Professional Licensing for Alaska Electricians' License Renewal.

Alaska Electrical Board Continuing Education Provider License#: 15766
  Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2023 Code Changes Update Part 28.0 NEC 19719 11/22/2023
-through-
11/22/2027
$75
-26

$49
Part 2 of this Alaska Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2023 NEC. Continuing in Article 314, all the way through NEC chapter 9 will be covered. Earns 8 hours of Electrical Continuing Education for Electrical License Renewal.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2023 Code Changes Update Part 2 Course Topics:
  • 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible.
  • Article 315 Medium Voltage Conductors, Cable, Cable Joints, and Cable Terminations.
  • 320.23(A) Cables Run Across the Top of Framing Members.
  • 334.10(2) Uses Permitted.
  • 334.15(B) Protection from Physical Damage.
  • 334.19 NM Cable Entries.
  • 334.24 Bending Radius.
  • 344.28 Reaming and Threading.
  • 352.44 Expansion Fittings and Earth Movement.
  • 358.10 Uses Permitted.
  • Article 369 Insulated Bus Pipe IBP/ Tubular Covered Conductors (TCC) Systems.
  • Article 371 Flexible Bus Systems.
  • Article 400 Part IV. Portable Power Feeder Cables Over 2000 Volts, Nominal.
  • 404.30 Switch Enclosures with Doors.
  • 406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  • 406.4(G) Protection of Floor Receptacles.
  • 406.6(D) Receptacle Faceplates with Integral Night Light and/or USB Charger.
  • 406.9(A) & (B) Receptacles in Damp or Wet Locations.
  • 406.9(C) Bathtub and Shower Space.
  • 406.12 Tamper-Resistant Receptacles.
  • 408.4(B) Source of Supply.
  • 408.9 Replacement Panelboards.
  • 408.38 Enclosure.
  • 410.10(D) Bathtub and Shower Areas.
  • 410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  • 440.8 Single Machine and Location.
  • 440.11 General.
  • 440.14 Location.
  • 445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  • 625.40 Electric Vehicle Branch Circuit.
  • 680.5 GFCI and SPGFCI Protection.
  • 680.12 Equipment Rooms, Vaults, and Pits.
  • 680.21(D) Pool Pump Motor Replacement.
  • 680.54(C) Equipotential Bonding of Splash Pads.
  • Figure 690.1.
  • 690.4(G) PV Equipment Floating on Bodies of Water.
  • 690.12 Rapid Shutdown of PV Systems on Buildings.
  • 690.15(D) Equipment Disconnecting Means.
  • 700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  • 700.12(H) Battery-Equipped Emergency Luminaires.
  • 700.27 Class 2 Powered Emergency Lighting Systems.
  • 700.32 Selective Coordination.
  • 705.11(A) Service Connections.
  • 705.11(B), (C), and (F) Conductors and Connections.
  • Article 722 Cables for Power-Limited Circuits and Fault-Managed Power Circuits.
  • Article 724 Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits.
  • 725.1 Scope.
  • 725.24 Mechanical Execution of Work.
  • 760.33 Supply-Side Overvoltage Protection.
  • Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other AK Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2026 Code Changes Update Part 1 Banner
NEC 2026 Code Changes Update Part 1
Course #: 20933
Credit Type: NEC
Credit Hours: 8.0
Price: $75
 
NEC 2026 Code Changes Update Part 2 Banner
NEC 2026 Code Changes Update Part 2
Course #: 20934
Credit Type: NEC
Credit Hours: 8.0
Price: $75
 
NEC 2023 Code Changes Update Part 1 Banner
NEC 2023 Code Changes Update Part 1
Course #: 19718
Credit Type: NEC
Credit Hours: 8.0
Price: $75
 
NEC 2023 Code Changes Update Part 2 Banner
NEC 2023 Code Changes Update Part 2
Course #: 19719
Credit Type: NEC
Credit Hours: 8.0
Price: $75