2023 NEC Code Changes Update part 2

Approved by the South Dakota Electrical Commission Department of Labor & Regulation for South Dakota Electricians License Renewal.

Yes! We Are Approved by the South Dakota Electrical Commission Department of Labor & Regulation for South Dakota Electricians' License Renewal.

South Dakota Electrical Board Continuing Education Provider License#: 152
Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 NEC Code Changes Update part 28.0 Code 6611 3/8/2023
-through-
8/31/2025
$79
-20

$59
This South Dakota Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2023 NEC. From Article 334 all the way through Chapter 9 will be covered. This course is great to learn all the new ideas from the 2020 NEC. After completing this course, the licensee will be able to apply NEC changes from what they have learned from topics ranging from Article 334 all the way through Chapter 9. This increases in effectiveness if combined with Part 1.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 NEC Code Changes Update part 2 Course Topics:
  334.10(2) Uses Permitted.
  334.15(B) Protection from Physical Damage.
  334.19 NM Cable Entries.
  334.24 Bending Radius.
  344.28 Reaming and Threading.
  352.44 Expansion Fittings and Earth Movement.
  Article 369 Insulated Bus Pipe IBP/ Tubular Covered Conductors (TCC) Systems.
  404.30 Switch Enclosures with Doors.
  406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  406.4(G) Protection of Floor Receptacles.
  406.6(D) Receptacle Faceplates with Integral Night Light and/or USB Charger.
  406.9(A) & (B) Receptacles in Damp or Wet Locations.
  406.9(C) Bathtub and Shower Space.
  406.12 Tamper-Resistant Receptacles.
  408.4(A) Circuit Directory or Circuit Description.
  408.4(B) Source of Supply.
  408.9 Replacement Panelboards.
  408.38 Enclosure.
  408.43 Panelboard Orientation.
  410.2 Reconditioned Equipment.
  410.10(D) Bathtub and Shower Areas.
  410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  410.184 GFCI Protection and SPGFCI Protection.
  422.18 Ceiling-Suspended (Paddle) Fans.
  424.48 Installation of Cables in Walls.
  430.52 Rating or Setting for Individual Motor Circuit.
  440.8 Single Machine and Location.
  440.11 General.
  440.14 Location.
  445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  500.4 Documentation.
  500.7 Protection Techniques.
  511.7 Fixed Wiring Above Class I Locations.
  Article 512 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials.
  517.10(B) Areas Not Covered by Part II of Article 517.
  517.13 Equipment Grounding Conductor for Receptacles and Fixed Electrical Equipment in Patient Care Spaces.
  547.26 Physical Protection.
  550.32 Service Equipment.
  555.4 Location of Service Equipment.
  555.15 Replacement of Equipment.
  555.35 Ground-Fault Protection of Equipment (GFPE) and Ground-Fault Circuit-Interrupter.
  555.36 Disconnecting Means for Shore Power Connection(s).
  625.40 Electric Vehicle Branch Circuit.
  630.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  680.5 GFCI and SPGFCI Protection.
  680.12 Equipment Rooms, Vaults, and Pits.
  680.14 Corrosive Environments.
  680.21(D) Pool Pump Motor Replacement.
  680.54(C) Equipotential Bonding of Splash Pads.
  Figure 690.1.
  690.2 Deletion of PV Output Circuit.
  690.7 Maximum Voltage.
  690.8(A) Calculation of Maximum Circuit Current.
  690.8(D) Multiple PV String Circuits.
  690.12 Rapid Shutdown of PV Systems on Buildings.
  690.12(A) Controlled Conductors and Rapid Shutdown.
  690.12(B) Controlled Limits.
  690.12(D) Buildings with Rapid Shutdown.
  690.15(D) Equipment Disconnecting Means.
  690.31(B) Identification and Grouping.
  690.43(C) Equipment Grounding Conductor Location.
  695.6(D) Fire Pump Wiring.
  700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  700.27 Class 2 Powered Emergency Lighting Systems.
  700.32 Selective Coordination.
  705.10 Identification of Power Sources.
  705.11(A) Service Connections.
  705.11(B), (C), and (F) Conductors and Connections.
  705.11(D) and (E) Service Disconnecting Means, Bonding and Grounding.
  705.12(A) Feeders.
  705.12(A) Feeder Taps.
  706.15 Disconnecting Means.
  725.1 Scope.
  760.33 Supply-Side Overvoltage Protection.
  Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other SD Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2023 NEC Code Changes Update part 1 Banner
2023 NEC Code Changes Update part 1
Course #: 6610
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
2023 NEC Code Changes Update part 2 Banner
2023 NEC Code Changes Update part 2
Course #: 6611
Credit Type: Code
Credit Hours: 8.0
Price: $79
 
Available Fault Current Banner
Available Fault Current
Course #: 6612
Credit Type: Code
Credit Hours: 4.0
Price: $45
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Course #: 6719
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Course #: 6715
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Course #: 6714
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Boxes and Enclosures Webinar (Webinar) Banner
Boxes and Enclosures Webinar (Webinar)
Course #: 6718
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
Passing the Inspection (Webinar) Banner
Passing the Inspection (Webinar)
Course #: 6717
Credit Type: Code
Credit Hours: 4.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Course #: 6716
Credit Type: Code
Credit Hours: 4.0
Price: $75