NEC 2023 Code Changes Update - 10 Hours

Approved by the Maryland DLLR Division of Occupational and Professional Licensing for Maryland Electricians License Renewal.

Yes! We Are Approved by the Maryland DLLR Division of Occupational and Professional Licensing for Maryland Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
NEC 2023 Code Changes Update - 10 Hours10.0 Code N/A 2/7/2024
-through-
2/7/2026
$99
-10

$89
This 10 Hour Maryland Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2023 NEC. From Article 90 Changes all the way through Chapter 9 will be covered. This course will earn you 10 hours of electrical continuing education for your electrical license renewal in MD.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
NEC 2023 Code Changes Update - 10 Hours Course Topics:
  90.5(C) Explanatory Material.
  Article 100.
  Article 100 Definitions. Accessible (as applied to wiring methods).
  Article 100 Definitions. Counter (Countertop).
  Article 100 Definitions. Likely to Become Energized.
  Article 100 Definitions. Work Surface.
  110.3(A)(8) Cybersecurity.
  110.3(B) Installation and Use.
  110.16(B) Service Equipment and Feeder Supplied Equipment.
  110.22(A) Identification of Disconnecting Means.
  110.26(A)(4) Limited Access.
  110.26(A)(6) Grade, Floor, or Working Platform.
  110.26(C)(2) Large Equipment.
  110.26(C)(3) Personnel Doors.
  110.26(E) Dedicated Equipment Space.
  110.29 In Sight From.
  200.6 Means of Identifying Grounded Conductors.
  Article 210.
  210.4 Multiwire Branch Circuits.
  210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  210.8(A) GFCI Protection for Dwelling Units.
  210.8(B) GFCI Protection for Other Than Dwelling Units.
  210.8(D) GFCI Protection for Specific Appliances.
  210.8(F) GFCI Protection for Outdoor Outlets.
  210.12 AFCI Protection.
  210.18 Branch Circuit Rating.
  210.19 Conductors - Minimum Ampacity and Size.
  210.52(A)(2) Wall Space for Dwelling Unit Receptacle Outlets.
  210.52(C) Dwelling Unit Receptacle Outlets at Countertops and Work Surfaces.
  210.52(C)(2) & (3) Island and Peninsular Countertops and Work Surfaces.
  225.41 Emergency Disconnects.
  230.7 Other Conductors.
  230.71(B) Two to Six Service Disconnecting Means.
  240.4(B) Overcurrent Devices Rated 800 Amperes or Less.
  240.6(D) Remotely Accessible Adjustable-Trip Circuit Breakers.
  240.11 Selective Coordination.
  240.60(E) Fuse Reducers.
  240.89 Replacement Trip Units.
  Article 245 Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 Volts dc.
  250.64(G) Enclosures with Ventilation Openings.
  250.68(C) Grounding Electrode Conductor Connections.
  250.102(C)(2) Size of SSBJ for Parallel Conductor Installations.
  250.140 Frames of Ranges and Clothes Dryers.
  Table 300.5 Minimum Cover Requirements.
  300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
  312.8(A) Splices, Taps, and Feed-Through Conductors.
  312.10 Screws or Other Fasteners.
  312.102 Doors or Covers.
  314.5 Screws or Other Fasteners.
  314.24(C) Clearances for Side-Wiring Entrances.
  314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible.
  Article 315 Medium Voltage Conductors, Cable, Cable Joints, and Cable Terminations.
  320.23(A) Cables Run Across the Top of Framing Members.
  334.10(2) Uses Permitted.
  334.15(B) Protection from Physical Damage.
  334.19 NM Cable Entries.
  334.24 Bending Radius.
  344.28 Reaming and Threading.
  352.44 Expansion Fittings and Earth Movement.
  358.10 Uses Permitted.
  Article 369 Insulated Bus Pipe IBP/ Tubular Covered Conductors (TCC) Systems.
  Article 371 Flexible Bus Systems.
  Article 400 Part IV. Portable Power Feeder Cables Over 2000 Volts, Nominal.
  404.30 Switch Enclosures with Doors.
  406.4(D)(8) Receptacle Replacements and Ground-Fault Protection of Equipment (GFPE).
  406.4(G) Protection of Floor Receptacles.
  406.6(D) Receptacle Faceplates with Integral Night Light and/or USB Charger.
  406.9(A) & (B) Receptacles in Damp or Wet Locations.
  406.9(C) Bathtub and Shower Space.
  406.12 Tamper-Resistant Receptacles.
  408.4(B) Source of Supply.
  408.9 Replacement Panelboards.
  408.38 Enclosure.
  410.10(D) Bathtub and Shower Areas.
  410.71 Disconnecting Means for Fluorescent or LED Luminaires that Utilize Double-Ended Lamps.
  440.8 Single Machine and Location.
  440.11 General.
  440.14 Location.
  445.18 & 19 Disconnecting Means and Emergency Shutdown of Prime Mover.
  625.40 Electric Vehicle Branch Circuit.
  680.5 GFCI and SPGFCI Protection.
  680.12 Equipment Rooms, Vaults, and Pits.
  680.21(D) Pool Pump Motor Replacement.
  680.54(C) Equipotential Bonding of Splash Pads.
  Figure 690.1.
  690.4(G) PV Equipment Floating on Bodies of Water.
  690.12 Rapid Shutdown of PV Systems on Buildings.
  690.15(D) Equipment Disconnecting Means.
  700.11 Wiring, Class-2-Powered Emergency Lighting Systems.
  700.12(H) Battery-Equipped Emergency Luminaires.
  700.27 Class 2 Powered Emergency Lighting Systems.
  700.32 Selective Coordination.
  705.11(A) Service Connections.
  705.11(B), (C), and (F) Conductors and Connections.
  Article 722 Cables for Power-Limited Circuits and Fault-Managed Power Circuits.
  Article 724 Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits.
  725.1 Scope.
  725.24 Mechanical Execution of Work.
  760.33 Supply-Side Overvoltage Protection.
  Chapter 9 Notes and Tables.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other MD Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2023 Code Changes Update - 5 Hours Banner
NEC 2023 Code Changes Update - 5 Hours
Credit Type: Code
Credit Hours: 5.0
Price: $55
 
NEC 2020 Code Changes Update Banner
NEC 2020 Code Changes Update
Credit Type: Code
Credit Hours: 5.0
Price: $55
 
NEC 2023 Code Changes Update - 10 Hours Banner
NEC 2023 Code Changes Update - 10 Hours
Credit Type: Code
Credit Hours: 10.0
Price: $99
 
Available Fault Current (Webinar) Banner
Available Fault Current (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
Electrical Equipment Working Space (Webinar) Banner
Electrical Equipment Working Space (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
PV Systems (Webinar) Banner
PV Systems (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
PV System Interconnections (Webinar) Banner
PV System Interconnections (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
Boxes and Enclosures (Webinar) Banner
Boxes and Enclosures (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
Passing the Electrical Inspection (Webinar) Banner
Passing the Electrical Inspection (Webinar)
Credit Type: Code
Credit Hours: 5.0
Price: $75
 
NEC 2020 Code Changes Update - 10 Hours Banner
NEC 2020 Code Changes Update - 10 Hours
Credit Type: Code
Credit Hours: 10.0
Price: $99