2023 Available Fault Current

Approved by the North Dakota State Electrical Board for North Dakota Electricians License Renewal.

Yes! We Are Approved by the North Dakota State Electrical Board for North Dakota Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 Available Fault Current4.0 Code ND #23-147 3/6/2024
-through-
4/30/2026
$49
-10

$39
This North Dakota Electrical Continuing Education License Renewal Course reviews Available Fault Current. *This course also contains a segment on North Dakota Laws, Rules, and Wiring Standards as required by the NDSEB to renew your license. Good for 4 hours of ND State Electrical Board renewal credit.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 Available Fault Current Course Topics:
  Available Fault Current.
  Available Fault Current and Characteristics of the Circuit.
  Available Fault Current. Understanding the Calculations.
  Available Fault Current. Example Calculation.
  Article 100 Definitions. Interrupting Rating.
  Article 100 Definitions. Short Circuit Current Rating.
  110.9 Interrupting Rating of Defensive and Passive Devices.
  110.9 Interrupting Rating.
  240.83(C) Circuit Breaker Marking. Interrupting Rating.
  110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  Available Fault Current. Applying It Downstream of the Service.
  110.16(A) Arc-Flash Hazard Warning. General.
  110.16(B) Arc-Flash Hazard Warning. Service Equipment.
  110.24(A) Available Fault Current. Field Marking.
  110.24(B) Available Fault Current. Modifications.
  Available Fault Current and Remodel or Service Work.
  Available Fault Current and Blueprints.
  Available Fault Current on the Plans. Exercise 1.
  Available Fault Current on the Plans. Exercise 2.
  Available Fault Current on the Plans. Exercise 3.
  Available Fault Current on the Plans. Exercise 4.
  Fully Rated Systems.
  Series Rated Systems.
  240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  110.22(B) Engineered Series Combination Systems.
  240.86(B) Series Rated Systems. Tested Combinations.
  110.22(C) Tested Series Combination Systems.
  Verifying a Tested Series Rated Combination. Circuit Breakers.
  Verifying a Tested Series Rated Combination. Fuses.
  NEC 110.3(B) and The Intermixing of Circuit breakers.
  240.86(C) Series Ratings. Motor Contribution Exercise 1.
  240.86(C) Series Ratings. Motor Contribution Exercise 2.
  Series Ratings and Selective Coordination.
  Circuit Breakers Protecting Circuit Breakers.
  Fuses Protecting Circuit Breakers.
  Fuse Protection of Passive Components.
  Selecting a Fuse Because of its Current Limiting Characteristics.
  Short-Circuit Current Ratings Dependent on Specific OCPDs.
  230.82(3) Equipment Connected to the Supply Side of Service Disconnect.
  Surge-Protective Devices. Short-Circuit Current Rating.
  Article 100 & 409.22 Industrial Control Panels.
  409.110 Industrial Control Panels. Marking.
  430.8 Marking on Motor Controllers.
  430.99 Motor Control Centers. Available Fault Current.
  440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  480.7 DC Disconnect Methods. Maximum Available Short-Circuit Current.
  620.16 Elevators. Short-Circuit Current Rating.
  700.5(E) Emergency System Transfer Equipment. Documentation.
  701.4 Legally Required Standby Systems. Capacity and Rating.
  24.1-06-01-10. Requirements for electrical installations.
  24.1-06-01-10. Requirements for electrical installations.
  24.1-06-01-10. Requirements for electrical installations.
  24.1-06-01-10. Requirements for electrical installations.
  24.1-06-01-20. Water damaged electrical equipment.
  24.1-06-01-30. Markings of means of egress, illumination of means of egress, and emergency lighting.
  24.1-06-01-40. Smoke alarms, heat alarms, fire alarm systems and carbon monoxide alarm requirements for evacuation and life safety.
  24.1-06-01-40. Smoke alarms, heat alarms, fire alarm systems and carbon monoxide alarm requirements for evacuation and life safety.
  24.1-06-01-40. Smoke alarms, heat alarms, fire alarm systems and carbon monoxide alarm requirements for evacuation and life safety.
  24.1-06-02-10. (NEC 210) Branch circuits.
  24.1-06-02-10. (NEC 210) Branch circuits.
  24.1-06-02-10. (NEC 210) Branch circuits.
  24.1-06-02-30. (NEC 230) Services.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other ND Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
NEC 2023 Code Changes Update Part 1 Banner
NEC 2023 Code Changes Update Part 1
Course #: ND #23-127
Credit Type: Code
Credit Hours: 8.0
Price: $95
 
2026 NEC Code Changes Update Part 1 Banner
2026 NEC Code Changes Update Part 1
Course #: ND #26-038
Credit Type: Code
Credit Hours: 8.0
Price: $95
 
NEC 2023 Code Changes Update Part 2 Banner
NEC 2023 Code Changes Update Part 2
Course #: ND #23-128
Credit Type: Code
Credit Hours: 8.0
Price: $95
 
2023 Grounding and Bonding Banner
2023 Grounding and Bonding
Course #: ND #23-148
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
2023 Available Fault Current Banner
2023 Available Fault Current
Course #: ND #23-147
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
Passing the Electrical Inspection Banner
Passing the Electrical Inspection
Course #: ND #23-149
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
2023 Theory and Calculations Banner
2023 Theory and Calculations
Course #: ND #23-150
Credit Type: Code
Credit Hours: 4.0
Price: $49
 
2026 NEC Code Changes Update Part 2 Banner
2026 NEC Code Changes Update Part 2
Course #: ND #26-039
Credit Type: Code
Credit Hours: 8.0
Price: $95