2024 NFPA 70E Electrical Safety in the Workplace

Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians License Renewal.

Yes! We Are Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2024 NFPA 70E Electrical Safety in the Workplace4.0 Core 21705 4/4/2024
-through-
4/4/2026
$69
-30

$39
This 4 Hour Utah Electrical Continuing Education License Renewal Course reviews electrical safety practices in accordance with the 2024 NFPA 70E Standard for Electrical Safety in the Workplace. Topics like PPE, energized work, safeguarding, shock & arc-flash protection are delivered in an easy to understand format using inspection photos, graphics & videos, commentary from code experts & more to explain the code language and apply it to real world installations. Earns 4 hours of “Core” continuing education credit for Utah Electrical License Renewal. Approved by the UT DOPL electrical board for you to renew in 2024.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2024 NFPA 70E Electrical Safety in the Workplace Course Topics:
  NFPA 70E Purpose and Scope.
  NFPA 70E 90.4 Standard Arrangement.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E 105.3 Responsibility.
  NFPA 70E 110.2 Electrically Safe Work Condition.
  NFPA 70E 110.2(B) Normal Operating Condition.
  NFPA 70E 110.3 Electrical Safety Program.
  NFPA 70E 110.3(H) Risk Assessment Procedure.
  NFPA 70E 110.3(I) Job Safety Planning and Job Briefing.
  NFPA 70E 110.3(L) Auditing.
  NFPA 70E 110.4(A)(1) Training Requirements. Qualified Person.
  NFPA 70E 110.4(A)(3) and (4) Additional Training and Retraining.
  NFPA 70E 110.4(B) Lockout/Tagout Procedure Training.
  NFPA 70E 110.6 Test Instruments and Equipment.
  NFPA 70E 110.6(E) Operation Verification.
  NFPA 70E 120.2 Lockout/Tagout Program & Responsibilities.
  NFPA 70E 120.3 Lockout/Tagout Principles.
  NFPA 70E 120.5(A)(4) Simple Lockout/Tagout Procedure.
  NFPA 70E 120.5(A)(5) Complex Lockout/Tagout.
  NFPA 70E 120.5(B)(1-3) Elements of Control.
  NFPA 70E 120.5(B)(4-6) Elements of Control.
  NFPA 70E 120.5(B)(7) Temporary Protective Grounding.
  NFPA 70E 120.5(B)(11) Lockout/Tagout Application.
  NFPA 70E 120.5(B)(13) Release for Return to Service.
  NFPA 70E 120.6(1-6) Process for Establishing and Verifying an Electrically Safe Work Condition.
  NFPA 70E 120.6(7) Testing for Absence of Voltage.
  NFPA 70E 120.6(8) Induced Voltage and Stored Electrical Energy.
  NFPA 70E 130.1 Scope.
  NFPA 70E 130.2 Electrically Safe Work Conditions VS Energized Work.
  NFPA 70E 130.2(B) Elements of an Energized Electrical Work Permit.
  NFPA 70E 130.2(C) Exemptions to an Energized Electrical Work Permit.
  NFPA 70E 130.4(E) and (F) Electric Shock Protection Boundaries.
  NFPA 70E Table 130.4(E)(a) Shock Protection Approach Boundaries.
  NFPA 70E Table 130.4(E)(B) Shock Protection Approach Boundaries.
  NFPA 70E Table 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 1.
  NFPA 70E Table 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 2.
  NFPA 70E Table 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 3.
  NFPA 70E Table 130.7(C)(15)(a) Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems. Exercise 1.
  NFPA 70E Table 130.5(C)(15)(a) Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems. Exercise 2.
  NFPA 70E Table 130.7(C)(15)(c) Protective Clothing and Personal Protective Equipment (PPE).
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other UT Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2023 NEC Changes Part 1 Banner
2023 NEC Changes Part 1
Course #: 21707
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2023 NEC Code Changes Update - 16 Hours w/4Hrs NFPA 70E Banner
2023 NEC Code Changes Update - 16 Hours w/4Hrs NFPA 70E
Course #: 23041
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 NEC Changes Part 2 Banner
2023 NEC Changes Part 2
Course #: 21709
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2024 NFPA 70E Electrical Safety in the Workplace Banner
2024 NFPA 70E Electrical Safety in the Workplace
Course #: 21705
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2020 NEC Update - 16 Hours w/4Hrs NFPA 70E Banner
2020 NEC Update - 16 Hours w/4Hrs NFPA 70E
Course #: 21695
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 Grounding and Bonding Banner
2023 Grounding and Bonding
Course #: 21699
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2026 NEC Update - 16 Hours w/4Hrs NFPA 70E Banner
2026 NEC Update - 16 Hours w/4Hrs NFPA 70E
Course #: 24393
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 Available Fault Current Banner
2023 Available Fault Current
Course #: 21697
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
Passing the Electrical Inspection Banner
Passing the Electrical Inspection
Course #: 21703
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2023 Theory and Calculations Banner
2023 Theory and Calculations
Course #: 21701
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2026 NEC Code Changes Update Part 1 Banner
2026 NEC Code Changes Update Part 1
Course #: 24297
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2026 NEC Code Changes Update Part 2 Banner
2026 NEC Code Changes Update Part 2
Course #: 24299
Credit Type: Core
Credit Hours: 8.0
Price: $99