2023 Available Fault Current

Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians License Renewal.

Yes! We Are Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians' License Renewal.

Electrical Online Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2023 Available Fault Current4.0 Core 21697 4/3/2024
-through-
4/3/2026
$69
-30

$39
This 4 hour Utah Electrical Continuing Education License Renewal Course takes the difficult concepts of available fault current, short circuit current ratings, fully rated and series rated electrical systems and places them in an easy to understand format. This course will earn you 4 hours of Electrical Continuing Education / Professional Development Units (PDUs) of credit type \'Core\' for your electrical license renewal in Utah.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2023 Available Fault Current Course Topics:
  Available Fault Current.
  Available Fault Current and Characteristics of the Circuit.
  Available Fault Current. Understanding the Calculations.
  Available Fault Current. Example Calculation.
  Article 100 Definitions. Interrupting Rating.
  Article 100 Definitions. Short Circuit Current Rating.
  110.9 Interrupting Rating of Defensive and Passive Devices.
  110.9 Interrupting Rating.
  240.83(C) Circuit Breaker Marking. Interrupting Rating.
  110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics.
  Available Fault Current. Applying It Downstream of the Service.
  110.16(A) Arc-Flash Hazard Warning. General.
  110.16(B) Arc-Flash Hazard Warning. Service Equipment.
  110.24(A) Available Fault Current. Field Marking.
  110.24(B) Available Fault Current. Modifications.
  Available Fault Current and Remodel or Service Work.
  Available Fault Current and Blueprints.
  Available Fault Current on the Plans. Exercise 1.
  Available Fault Current on the Plans. Exercise 2.
  Available Fault Current on the Plans. Exercise 3.
  Available Fault Current on the Plans. Exercise 4.
  Fully Rated Systems.
  Series Rated Systems.
  240.86(A) Series Rated Systems. Selected Under Engineering Supervision in Existing Installations.
  110.22(B) Engineered Series Combination Systems.
  240.86(B) Series Rated Systems. Tested Combinations.
  110.22(C) Tested Series Combination Systems.
  Verifying a Tested Series Rated Combination. Circuit Breakers.
  Verifying a Tested Series Rated Combination. Fuses.
  NEC 110.3(B) and The Intermixing of Circuit breakers.
  240.86(C) Series Ratings. Motor Contribution Exercise 1.
  240.86(C) Series Ratings. Motor Contribution Exercise 2.
  Series Ratings and Selective Coordination.
  Circuit Breakers Protecting Circuit Breakers.
  Fuses Protecting Circuit Breakers.
  Fuse Protection of Passive Components.
  Selecting a Fuse Because of its Current Limiting Characteristics.
  Short-Circuit Current Ratings Dependent on Specific OCPDs.
  230.82(3) Equipment Connected to the Supply Side of Service Disconnect.
  Surge-Protective Devices. Short-Circuit Current Rating.
  Article 100 & 409.22 Industrial Control Panels.
  409.110 Industrial Control Panels. Marking.
  430.8 Marking on Motor Controllers.
  430.99 Motor Control Centers. Available Fault Current.
  440.4 Marking on Hermetic Refrigerant Motor-Compressors and Equipment.
  440.10 HVAC Multimotor and Combination-Load Equipment. Short-Circuit Current Rating.
  480.7 DC Disconnect Methods. Maximum Available Short-Circuit Current.
  620.16 Elevators. Short-Circuit Current Rating.
  700.5(E) Emergency System Transfer Equipment. Documentation.
  701.4 Legally Required Standby Systems. Capacity and Rating.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other UT Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2023 NEC Changes Part 1 Banner
2023 NEC Changes Part 1
Course #: 21707
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2023 NEC Code Changes Update - 16 Hours w/4Hrs NFPA 70E Banner
2023 NEC Code Changes Update - 16 Hours w/4Hrs NFPA 70E
Course #: 23041
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 NEC Changes Part 2 Banner
2023 NEC Changes Part 2
Course #: 21709
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2024 NFPA 70E Electrical Safety in the Workplace Banner
2024 NFPA 70E Electrical Safety in the Workplace
Course #: 21705
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2020 NEC Update - 16 Hours w/4Hrs NFPA 70E Banner
2020 NEC Update - 16 Hours w/4Hrs NFPA 70E
Course #: 21695
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 Grounding and Bonding Banner
2023 Grounding and Bonding
Course #: 21699
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2023 Available Fault Current Banner
2023 Available Fault Current
Course #: 21697
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
Passing the Electrical Inspection Banner
Passing the Electrical Inspection
Course #: 21703
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E Banner
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E
Course #: 21689
Credit Type: Core
Credit Hours: 12.0
Price: $129
 
2026 NEC Update - 16 Hours w/4Hrs NFPA 70E Banner
2026 NEC Update - 16 Hours w/4Hrs NFPA 70E
Course #: 24393
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 Theory and Calculations Banner
2023 Theory and Calculations
Course #: 21701
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2026 NEC Code Changes Update Part 1 Banner
2026 NEC Code Changes Update Part 1
Course #: 24297
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2026 NEC Code Changes Update Part 2 Banner
2026 NEC Code Changes Update Part 2
Course #: 24299
Credit Type: Core
Credit Hours: 8.0
Price: $99