312.6 Deflection of Conductors.

Conductors at terminals or conductors entering or leaving cabinets, cutout boxes, and meter socket enclosures shall comply with 312.6(A) through (C).
Click to Enlarge
Conductors at terminals or conductors entering or leaving cabinets, cutout boxes, and meter socket enclosures shall comply with 312.6(A) through (C).

Code Change Summary: Revised code language now addresses deflection of conductors (wire-bending space) in meter socket enclosures.

NEC Article 312 is all about cabinets, cutout boxes and meter socket enclosures and provides specific measurements to ensure conductors can be properly deflected within the enclosures. In the past, for some reason, Section 312.6 required conductors at terminals or conductors entering or leaving cabinets or cutout boxes “and the like” to comply with the deflection rules in 312.6(A) through (C).

“And the like” is a bit confusing, especially when the article is only about three specific types of enclosures: cabinets, cutout boxes and meter socket enclosures.

In the 2020 NEC®, a public input (code change proposal) was accepted to simply add meter socket enclosures to the list of equipment that requires space for conductor deflection. Knowing the rules and selecting the correct table in Article 312 is important. The notes under the tables are also important since some enclosures have lay-in type lugs which allow for a conductor to easily lay into place rather than resorting to bending the conductor tightly in order to terminate it as required for other than lay-in type lugs (see image). This results in reduced measurements when lay-in lugs are present.

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2020 NEC® edition of NFPA 70.

2017 Code Language:

312.6 Deflection of Conductors. Conductors at terminals or conductors entering or leaving cabinets or cutout boxes and the like shall comply with 312.6(A) through (C).

2020 Code Language:

312.6 Deflection of Conductors. Conductors at terminals or conductors entering or leaving cabinets, cutout boxes, and meter socket enclosures shall comply with 312.6(A) through (C).

Did You Like This? Let Us Know With A Like! Thanks!

312.6 Deflection of Conductors.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following must comply with the rules in 312.6(A) through (C)?

A: Conductors entering or leaving receptacle boxes.
B: Conductors entering or leaving switch boxes.
C: Conductors entering or leaving device boxes.
D: Conductors entering or leaving cabinets, cutout boxes, and meter socket enclosures.
Please register or sign in for electrical continuing education courses.