314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies

Use the image to help answer the question. Some feel that there may be an issue with the spray foam behind the box in contact with the NM cable. See NEMA bulletin 95 for additional information.
Click to Enlarge
Use the image to help answer the question. Some feel that there may be an issue with the spray foam behind the box in contact with the NM cable. See NEMA bulletin 95 for additional information.
Table 314.16(B) Volume Allowance Required Per Conductor
CONDUCTOR SIZE in.3
18 1.50
16 1.75
14 2.00
12 2.25
10 2.50
8 3.00
6 5.00

NEC Table 314.16(B) provides volume allowances to be used when calculating the number of 18 AWG through 6 AWG conductors permitted in a box.

Section 314.16(B)(1) requires each conductor that originates outside the box and terminates or is spliced within the box to be counted once, and each conductor passing through the box without splice or termination is also counted once.

Section 314.16(B)(2) is all about clamp fill. “Where one or more internal cable clamps, whether factory or field supplied, are present in the box, a single volume allowance in accordance with Table 314.16(B) shall be made based on the largest conductor present in the box”.

Section 314.16(B)(4) covers devices or equipment installed in the box. A typical duplex receptacle or light switch requires a double volume allowance to be made based on the largest wire terminating to the device.

Section 314.16(B)(5) covers equipment grounding conductors. “Where one or more equipment grounding conductors or equipment bonding jumpers enter a box, a single volume allowance in accordance with Table 314.16(B) shall be made based on the largest equipment grounding conductor or equipment bonding jumper present in the box”.

For complete code sections, refer to the actual NEC® text at NFPA.ORG. Once there, click on their link to free access to the 2017 NEC® edition of NFPA 70.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Refer to the image of the single-gang box with no cable clamps.

If this box containing 14 AWG conductors will have a blank cover and no devices, what is the total box fill?

A: 12 cubic inches.
B: 14 cubic inches.
C: 20 cubic inches.
D: 16 cubic inches.
Please register or sign in for electrical continuing education courses.