OESC 406.12 Replacements.

Replacement receptacles in Oregon have special allowances when it comes to AFCI requirements.
Click to Enlarge

Replacement receptacles in Oregon have special allowances when it comes to AFCI requirements.

NEC Section 406.12(D) provides rules to follow when replacing existing receptacles. The NEC® states the following:

406.12(D)(4) Arc-Fault Circuit-Interrupter Protection.

If a receptacle supplied by a 120-volt, single-phase, 15- or 20-ampere branch circuit located in any areas specified in 210.12(B), 210.12(C), or 210.12(D) is replaced, a replacement receptacle at this outlet shall be one of the following:

(1) A listed outlet branch-circuit type AFCI receptacle

(2) A receptacle protected by a listed outlet branch-circuit type AFCI type receptacle

(3) A receptacle protected by a listed combination type AFCI circuit breaker

Oregon has amended the above code language and deleted the requirements. Below is the Oregon version of NEC® 406.12(D)(4):

406.12(D)(4) Arc-Fault Circuit Interrupter Protection. (Not adopted by the State of Oregon)

Oregon amendments to the 2026 NEC® are located in “Table 1-E” of the Oregon Electrical Specialty Code (OESC) which can be seen using the following link or the OESC PDF file located near the bottom of the screen: https://www.oregon.gov/bcd/codes-stand/Documents/26oesc-table1-E.pdf

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

OESC 406.12 Replacements.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

In Oregon, which of the following is true regarding receptacle replacements in an older home where AFCI protection was not originally code required?

A: AFCI protection is required for all dwelling unit receptacle replacements.
B: AFCI protection is not required for replacement receptacles in Oregon.
C: A replacement receptacle in a bedroom must be AFCI protected.
D: A replacement receptacle in a hallway must be AFCI protected.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.