In Oregon, AFCI protection is not required for individual branch circuits that serve an appliance that is not easily moved or that is fastened in place
Oregon has heavily amended the code language below regarding AFCI protection:
OESC 210.12(B) Dwelling Units. All 120-volt, single phase, 10-, 15- and 20-ampere branch circuits supplying outlets or devices installed in the following locations shall be protected by any of the means described in 210.12(A):
Items (1) through (13) remain unchanged.
(14) Similar areas Not adopted by the State of Oregon
(15) Alcoves
[Exceptions No.1 and 2 remain unchanged]
Exception No 3: AFCI protection shall not be required for individual branch circuits that serve an appliance that is not easily moved or that is fastened in place.
Oregon amendments to the 2026 NEC® are located in “Table 1-E” of the Oregon Electrical Specialty Code (OESC) which can be seen using the following link or the OESC PDF file located near the bottom of the screen: https://www.oregon.gov/bcd/codes-stand/Documents/26oesc-table1-E.pdf
In Oregon, which of the following is true of a single-phase, 120-volt, 15-amp, branch circuit supplying an appliance that is fastened in place in a dwelling unit?