80.19 Permits and certificates.

Rule 818. Section 80.19, is added to the code to read as follows:

80.19. Permits and approvals. Permits and approvals shall conform to (a) to (e).

(a) Application. A copy of the permit shall be posted or otherwise readily accessible at each work site or carried by the permit holder as specified by the authority having jurisdiction.

(b) Issuance of Permits. The authority having jurisdiction shall be authorized to establish and issue permits, certificates, notices, and approvals, or orders pertaining to electrical safety hazards, except that no permit shall last longer than 180 days, or be required to execute any of the classes of electrical work specified in the following:

(1) Installation or replacement of equipment such as lamps and of electric utilization equipment approved for connection to suitable permanently installed receptacles.

(2) Replacement of flush or snap switches, fuses, lamp sockets, and receptacles, and other minor maintenance and repair work, such as replacing worn cords and tightening connections on a wiring device and minor repair work as defined in skilled trades regulation act, 2016 PA 407, MCL 339.5101 to 339.6133.

(3) The process of manufacturing, testing, servicing, or repairing electrical equipment or apparatus.

(4) Installations that are referred to in section 737(3)(a), (b), (c), (d), (f), (h), (l), and (m) of the skilled trades regulations act, 2016 PA 407, MCL 339.5737.

(c) Annual permits. In lieu of an individual permit for each installation or alteration, an annual permit shall, upon application, be issued to any person, firm, or corporation regularly employing 1 or more employees for the installation, alteration, and maintenance of electrical equipment in or on buildings or premises owned or occupied by the applicant for the permit. Upon application, an electrical contractor as an agent for the owner or tenant shall be issued an annual permit. The applicant shall keep records of all work done, and the records shall be transmitted periodically to the electrical inspector.

(d) Inspection and approvals.

(1) Upon the completion of any installation of electrical equipment that has been made under a permit, the person, firm, or corporation making the installation shall notify the electrical inspector having jurisdiction.

(2) Where the inspector finds the installation to be in conformity with the code, state statutes, rules and, if applicable, local ordinances, the inspector shall issue to the person, firm, or corporation making the installation a final approval, or certificate of approval provided payment has been made, which authorizes the connection into the supply of electricity.

(3) When any portion of the electrical installation within the jurisdiction of an electrical inspector is to be hidden from view by the permanent placement of parts of the building, the person, firm, or corporation installing the equipment shall notify the electrical inspector, and the equipment shall not be concealed until it has been approved by the electrical inspector. Neither the code official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection.

(e) Applications and extensions. The authority having jurisdiction may grant one 180-day extension of the original permit time period of 180 days, upon presentation of the permittee of a satisfactory reason for failure to start or complete the work or activity authorized by the permit.

Refer to the Department of Licensing and Regulatory Affairs 2017 Michigan electrical code rules part 8 to answer the question below.

  Click here to review the Michigan Part 8 Electrical Code  

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

80.19 Permits and certificates.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

In Michigan, which of the following is true regarding electrical permits and certificates?

A: Permits are issued when the first inspection has been called for the installed work.
B: A final inspection certificate authorizes the connection into the supply of electricity.
C: Changing lamps in a luminaire requires a written permit.
D: Inspections to receive a final inspection certificate are automatically scheduled for the day before the expiration of the permit.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.