WAC 296-46B-410 Equipment for general use — Luminaires, lampholders, and lamps.

Click to Enlarge

WAC 296-46B-410 Luminaires, lampholders, and lamps.

010 Luminaires in specific locations.

(1) All luminaires within an enclosed shower area or within five feet of the waterline of a bathtub must be enclosed, unless specifically listed for such use; these luminaires, with exposed metal parts that are grounded, must be ground fault circuit interrupter protected.

042 Luminaires with exposed conductive surfaces.

(2) Replacement luminaires that are directly wired or attached to boxes supplied by wiring methods that do not provide a ready means for grounding and that have exposed conductive surfaces will be permitted only where the luminaires are provided with ground-fault circuit-interrupter protection and marked "no equipment ground."

062 Flexible cord connection of electric discharge luminaires.

(3) A ground-type attachment plug cap and receptacle connection at the source junction box is not required when the flexible cord complies with NEC® 410.62 and the following:

(a) Connection to a source junction box must utilize an approved cable connector or clamp;

(b) The maximum length of the cord for a suspended pendant drop from a permanently installed junction box to a suitable tension take-up device above the pendant luminaire must not exceed six feet;

(c) The flexible cord must be supported at each end with an approved cord grip or strain relief connector fitting/device that will eliminate all stress on the conductor connections;

(d) The flexible cord must be a minimum #14 AWG copper;

(e) The flexible cord ampacity must be determined in NEC® Table 400.5(A) column A;

(f) The flexible cord must be hard or extra hard usage; and

(g) A vertical flexible cord supplying electric discharge luminaires must be secured to the luminaire support as per NEC® 334.30(A).

  Click here to review the Washington Administrative Code  

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

WAC 296-46B-410 Equipment for general use — Luminaires, lampholders, and lamps.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

In Washington, which of the following is true in order to install a flexible cord connected electric discharge luminaire without a grounding-type attachment plug cap and receptacle connection?

A: The circuit must be GFCI protected.
B: The minimum length of the cord is 6 feet.
C: The flexible cord must be listed for extreme use and supported at either end.
D: The flexible cord must be a minimum #14 AWG copper.
Please register or sign in for electrical continuing education courses.