Article 100. Bonding Jumper, Supply-Side.

The supply-side bonding jumper ensures the required electrical conductivity between metal parts required to be electrically connected.
Click to Enlarge

The supply-side bonding jumper ensures the required electrical conductivity between metal parts required to be electrically connected.

A supply-side bonding jumper (SSBJ) is a conductor installed on the supply side of a service or within service equipment enclosures, or for a separately derived system, that ensures the required electrical conductivity between metal parts required to be electrically connected. Unfortunately, the definition does not describe what can be used as a SSBJ.

At present, the only code section providing any possible clarity on what constitutes a SSBJ is highlighted in yellow below. This section only pertains to a SSBJ used in a separately derived system:

250.30(A)(2) Supply-Side Bonding Jumper. If the source of a separately derived system and the first disconnecting means are located in separate enclosures, a supply-side bonding jumper shall be installed with the circuit conductors from the source enclosure to the first disconnecting means enclosure. A supply-side bonding jumper shall not be required to be larger than the derived ungrounded conductors. The supply-side bonding jumper shall be permitted to be of nonflexible metal raceway type or of the wire or bus type as follows:

(1) A supply-side bonding jumper of the wire type shall comply with 250.102(C), based on the size of the derived ungrounded conductors.

(2) A supply-side bonding jumper of the bus type shall have a cross-sectional area not smaller than a supply-side bonding jumper of the wire type as determined in 250.102(C).

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to NFPA 70.

2026 Code Language:

Article 100.

Bonding Jumper, Supply-Side. (Supply-Side Bonding Jumper). A component of the effective ground-fault current path that is installed on the supply side of a service or within a service equipment enclosure(s), or for a separately derived system, that ensures the required electrical conductivity between metal parts required to be electrically connected.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Article 100. Bonding Jumper, Supply-Side.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following ensures the required electrical conductivity between metal parts required to be electrically connected on the supply side of a service?

A: The equipment grounding conductor.
B: The supply-side bonding jumper.
C: The main bonding jumper.
D: The system bonding jumper.
Please register or sign in for electrical continuing education courses.