NFPA 70E 120.5(B)(4-6) Elements of Control.

Once a disconnecting switch is locked in the open position, grab the handle, and try to turn it back on. Always double check and verify that the equipment cannot be restarted before starting to work on the equipment.
Click to Enlarge
Once a disconnecting switch is locked in the open position, grab the handle, and try to turn it back on. Always double check and verify that the equipment cannot be restarted before starting to work on the equipment.

When working on electrical equipment it is critical to ensure that all sources of energy related to the equipment have been properly controlled. As well, before the actual work takes place, it is important to verify that the equipment cannot be restarted.

Once a disconnecting means is locked in the open (off) position, grab the handle and try to turn it back on. Try to operate the equipment controls such as push-buttons, selector switches, and electrical interlocks. Always double check and verify that the equipment cannot be restarted before starting to work on the equipment.

Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.

120.5(B) Elements of Control. The procedure shall identify elements of control.

(4) Responsibility. The procedure shall identify the person who is responsible for verifying that the lockout/tagout procedure is implemented and who is responsible for ensuring that the task is completed prior to removing locks/tags. A mechanism to accomplish lockout/tagout for multiple (complex) jobs/tasks where required, including the person responsible for coordination, shall be included.

(5) Verification. The procedure shall verify that equipment cannot be restarted. The equipment operating controls, such as push-buttons, selector switches, and electrical interlocks, shall be operated or otherwise it shall be verified that the equipment cannot be restarted.

(6) Testing. The procedure shall establish the following:

(1) Test instrument to be used, the required PPE, and the person who will use it to verify proper operation of the test instrument on a known voltage source before and after use

(2) Requirement to define the boundary of the electrically safe work condition

(3) Requirement to test before touching every exposed conductor or circuit part(s) within the defined boundary of the work area

(4) Requirement to retest for absence of voltage when circuit conditions change or when the job location has been left unattended

(5) Planning considerations that include methods of verification where there is no accessible exposed point to take voltage measurements

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

NFPA 70E 120.5(B)(4-6) Elements of Control.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding the Lockout/tagout procedure?

A: The procedure shall require a test before touching any concealed conductor or circuit part(s) outside the defined work area boundary.
B: The procedure shall ensure that there are no accessible exposed points to take voltage measurements.
C: The procedure shall verify that equipment cannot be restarted.
D: The procedure must include a periodic retest for presence of voltage when circuit conditions remain unchanged or when the job location has been attended.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.