NFPA 70E 110.3 Electrical Safety Program.

An electrical safety program including electrical safety procedures should be in place for those whose work involves electrical hazards.
Click to Enlarge
An electrical safety program including electrical safety procedures should be in place for those whose work involves electrical hazards.

An electrical safety program including electrical safety procedures should be in place for those whose work involves electrical hazards.

Before energized work takes place, electrical safety program procedures must be created and customized for the specific task. The procedures should identify the safeguards to be used before the actual work is started.

An electrical safety program is essential for any workplace where employees are exposed to electrical hazards. This program serves as a foundational framework to ensure all safety measures are consistently applied and adhered to. It is designed to prevent electrical accidents and injuries, thereby safeguarding the health and safety of workers.

For an effective electrical safety program, specific procedures tailored to the nature of the work and the associated risks must be developed. These procedures are not one-size-fits-all but should be customized to reflect the particular circumstances of each task or environment. This customization ensures that the procedures are relevant and that workers can implement them effectively.

Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.

110.3 Electrical Safety Program.

(A) General. The employer shall implement and document an overall electrical safety program that directs activity appropriate to the risk associated with electrical hazards.

Informational Note No. 1: Safety-related work practices such as verification of proper maintenance and installation, alerting techniques, auditing requirements, and training requirements provided in this standard are administrative controls and part of an overall electrical safety program.

(G) Electrical Safety Program Procedures. An electrical safety program shall identify the procedures to be utilized before work is started by employees exposed to an electrical hazard.

Informational Note: See Informative Annex E for an example of a typical electrical safety program procedure.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

NFPA 70E 110.3 Electrical Safety Program.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding the electrical safety program?

A: The employee shall implement and document an overall electrical safety program.
B: The employee is responsible for establishing an electrical safety program.
C: Safety procedures used for the project must be identified after the work is complete.
D: Safety procedures must be identified before the work is started.