Grounding Versus Bonding.

In this installation, the wire type equipment grounding conductor is also used to bond non-current carrying metal enclosures to each other since the PVC raceway between the enclosures does not bond the metal lighting contactor box.
Click to Enlarge
In this installation, the wire type equipment grounding conductor is also used to bond non-current carrying metal enclosures to each other since the PVC raceway between the enclosures does not bond the metal lighting contactor box.

Grounding is the process of connecting something to the earth. This is typically accomplished through the grounding electrode system.

An equipment grounding conductor (EGC) connects the non-current carrying metal parts of equipment and metal enclosures to the grounded conductor at the service or separately derived system, which in turn is connected to the grounding electrode system, thus providing a low impedance path to carry fault current in the event of a fault to ground occurring in an electrical system circuit.

Bonding is the process of joining metal enclosures, equipment, raceways, metal water piping, gas piping, structural steel, and the like together. Bonding items together and connecting the bonded items to an equipment grounding conductor places everything at the same potential and ensures an effective ground-fault current path in the event of a fault to ground occurring in an electrical system circuit.

Sometimes the same wire can serve both as an equipment grounding conductor and as an equipment bonding jumper.

Below are a few of the NEC® Article 100 definitions pertaining to bonding and grounding:

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to NFPA 70.

2023 Code Language:

Article 100:

Bonded (Bonding). Connected to establish electrical continuity and conductivity.

Bonding Conductor or Bonding Jumper. A conductor that ensures the required electrical conductivity between metal parts that are required to be electrically connected.

Bonding Jumper, Equipment. (Equipment Bonding Jumper). The connection between two or more portions of the equipment grounding conductor.

Bonding Jumper, Main. (Main Bonding Jumper). The connection between the grounded circuit conductor and the equipment grounding conductor, or the supply-side bonding jumper, or both, at the service.

Ground. The earth.

Grounded (Grounding). Connected (connecting) to ground or to a conductive body that extends the ground connection.

Grounded, Solidly. (Solidly Grounded). Connected to ground without inserting any resistor or impedance device.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Grounding Versus Bonding.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true?

A: “Bonded” means connected to ground without inserting any resistor or impedance device.
B: “Ground” is the connection between two or more portions of the equipment grounding conductor.
C: When something is bonded, it is connected to establish electrical continuity and conductivity.
D: When something is grounded, it is connected to establish electrical continuity and conductivity.