OESC 210.52(E)(3) Balconies, Decks, and Porches.

In Oregon, decks or porches located at grade level with an area of less than 20 sq. ft. are not required to have an additional receptacle installed.
Click to Enlarge
In Oregon, decks or porches located at grade level with an area of less than 20 sq. ft. are not required to have an additional receptacle installed.

According to NEC® 210.52(E)(3), balconies, decks, and porches that are attached to the dwelling unit and are accessible from inside the dwelling unit shall have at least one receptacle outlet accessible from the balcony, deck, or porch. The receptacle outlet shall not be located more than 6 ½ ft above the balcony, deck, or porch walking surface.

In Oregon, the following exceptions have been added to omit the receptacle for smaller balconies, decks and porches:

Exception No. 1 to (3): Decks or porches located at grade level with an area of less than 1.9 m2 (20 ft2) are not required to have an additional receptacle installed.

Exception No. 2 to (3): Decks or porches located above grade level with a depth of 304 mm (1 ft) or less measured from the outside of the wall to the outside of the framing member are not required to have an additional receptacle installed.

Oregon amendments to the 2023 NEC® are located in “Table 1-E” of the Oregon Electrical Specialty Code (OESC) which can be seen using the following link or the OESC PDF file located near the bottom of the screen: 2023 OESC

  Click here to view the OESC  

Did You Like This? Let Us Know With A Like! Thanks!

OESC 210.52(E)(3) Balconies, Decks, and Porches.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

One of the following dwelling unit decks does NOT require a 15 or 20-ampere, 125-volt, single phase receptacle outlet. Which of the following dwelling unit decks does NOT require a 15 or 20-ampere, 125-volt, single phase receptacle outlet?

A: A grade level deck measuring 8 feet X 20 feet.
B: A grade level deck measuring 10 feet X 10 feet.
C: An above grade deck, connected to and accessible from inside the dwelling, measuring 15 square feet.
D: A grade level deck measuring 15 square feet.
Please register or sign in for electrical continuing education courses.