OESC 210.12(C) Arc-Fault Circuit-Interrupter Protection. Dormitory Units.

In Oregon, AFCI protection is not required for branch circuits supplying outlets or devices in a dorm bathroom or similar room.
Click to Enlarge
In Oregon, AFCI protection is not required for branch circuits supplying outlets or devices in a dorm bathroom or similar room.

Oregon has heavily amended the code language below regarding AFCI protection:

OESC 210.12(B) Dormitory Units. All 120-volt, single-phase, 10-, 15-, and 20- ampere branch circuits supplying outlets or devices installed in the following locations shall be protected by any of the means described in 210.12(A)(1) through (7) (6).

Items (1) through (4) remain unchanged.

(5) Bathrooms Not adopted by the State of Oregon

(6) Similar rooms Not adopted by the State of Oregon

(7) Study areas

Oregon amendments to the 2023 NEC® are located in “Table 1-E” of the Oregon Electrical Specialty Code (OESC) which can be seen using the following link or the OESC PDF file located near the bottom of the screen: 2023 OESC

  Click here to view the OESC  

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

OESC 210.12(C) Arc-Fault Circuit-Interrupter Protection. Dormitory Units.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

In Oregon, which of the following is true of AFCI protection?

A: All branch circuits supplying outlets in a dorm bathroom shall have AFCI protection.
B: Branch circuits supplying outlets in a dorm bathroom are NOT required to have AFCI protection.
C: All receptacles in a dorm bathroom shall have AFCI protection.
D: All branch circuits passing through a dorm bathroom shall have AFCI protection.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.