An electrical safety program including electrical safety procedures should be in place for those whose work involves electrical hazards.
Before energized work takes place, electrical safety program procedures must be created and customized for the specific task. The procedures should identify the safeguards to be used before the actual work is started.
Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.
110.5 Electrical Safety Program.
(A) General. The employer shall implement and document an overall electrical safety program that directs activity appropriate to the risk associated with electrical hazards.
Informational Note No. 1: Safety-related work practices such as verification of proper maintenance and installation, alerting techniques, auditing requirements, and training requirements provided in this standard are administrative controls and part of an overall electrical safety program.
(G) Electrical Safety Program Procedures. An electrical safety program shall identify the procedures to be utilized before work is started by employees exposed to an electrical hazard.
Informational Note: For an example of a typical electrical safety program procedure, see Informative Annex E.
Which of the following is true regarding the electrical safety program?
| Please register or sign in for electrical continuing education courses. If you were already signed in, your session probably expired, please sign back in. |