Available Fault Current. Applying It Downstream of the Service.

Many factors need to be known in order to determine compliance with NEC 110.10.
Click to Enlarge
Many factors need to be known in order to determine compliance with NEC 110.10.

Since the 1965 NEC®, electricians have been required by the code to consider equipment short-circuit current ratings (SCCR’s), circuit impedance, the speed at which overcurrent devices operate and other circuit characteristics in order to ensure that any installed overcurrent device can eliminate an overcurrent condition before the equipment being protected sustains extensive damage. This language is in NEC® 110.10.

The image shows a 20-amp rated time clock with a SCCR of 5,000 amperes (5kA). The 20-amp time clock complies with 110.9 as long as it is used to control no more than 20 amperes of electrical load. In order for the time clock to comply with NEC® 110.10, it must be installed in a way that it will never be subjected to more than 5,000 amps of available fault current. That being said, is it ok to install the time clock right next to the panelboard through a short offset fitting and supply it with just two feet of 12 AWG copper wire?

A few questions need to be asked in order to provide an answer to the above dilemma:

See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on the “free access” tab and select the applicable year of NFPA 70 (National Electrical code).

2017-2023 Code Language:

110.10 Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics. The overcurrent protective devices, the total impedance, the equipment short-circuit current ratings, and other characteristics of the circuit to be protected shall be selected and coordinated to permit the circuit protective devices used to clear a fault to do so without extensive damage to the electrical equipment of the circuit. This fault shall be assumed to be either between two or more of the circuit conductors or between any circuit conductor and the equipment grounding conductor(s) permitted in 250.118. Listed equipment applied in accordance with their listing shall be considered to meet the requirements of this section.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Available Fault Current. Applying It Downstream of the Service.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding compliance with NEC 110.10?

A: All fuses are listed as “current limiting”.
B: All breakers are listed as “current limiting”.
C: The available fault current value is only important at the service equipment.
D: The available fault current must be known even for equipment fed downstream of the electrical service.