NFPA 70E 130.4 Shock Protection Boundaries.

If the zombie needs to walk past the green line into the limited approach boundary, he must be advised by and escorted by a qualified person.
Click to Enlarge
If the zombie needs to walk past the green line into the limited approach boundary, he must be advised by and escorted by a qualified person.

In Section 130.4(D) of NFPA 70E, there are two shock protection boundaries that apply to personnel approaching exposed energized electrical conductors or circuit parts:

  1. The limited approach boundary
  2. The restricted approach boundary

These boundaries are determined from using two separate tables:

It is critical to understand that in certain instances, the arc flash boundary might be a greater distance from the energized electrical conductors or circuit parts than the limited approach boundary. The shock protection boundaries and the arc flash boundary are completely different and independent of each other.

Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.

130.4(E) Limited Approach Boundary.

(1) Approach by Unqualified Persons. Unless permitted by 130.4(E)(3), no unqualified person shall be permitted to approach nearer than the limited approach boundary of energized conductors and circuit parts.

(2) Working at or Close to the Limited Approach Boundary. Where one or more unqualified persons are working at or close to the limited approach boundary, the designated person in charge of the work space where the electrical hazard exists shall advise the unqualified person(s) of the electrical hazard and warn him or her to stay outside of the limited approach boundary.

(3) Entering the Limited Approach Boundary. Where there is a need for an unqualified person(s) to cross the limited approach boundary, a qualified person shall advise the unqualified person(s) of the possible hazards and continuously escort the unqualified person(s) while inside the limited approach boundary. Under no circumstance shall unqualified person(s) be permitted to cross the restricted approach boundary.

130.4(F) Restricted Approach Boundary. No qualified person shall approach or take any conductive object closer to exposed energized electrical conductors or circuit parts than the restricted approach boundary set forth in Table 130.4(D)(a) and Table 130.4(D)(b), unless one of the following conditions applies:

(1) The qualified person is insulated or guarded from energized electrical conductors or circuit parts operating at 50 volts or more. Insulating gloves and sleeves are considered insulation only with regard to the energized parts upon which work is performed.

(2) The energized electrical conductors or circuit parts are insulated from the qualified person and from any other conductive object at a different potential.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

NFPA 70E 130.4 Shock Protection Boundaries.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding boundaries in NFPA 70E?

A: The shock protection boundary and the arc flash boundary are completely different and independent of each other.
B: The shock protection boundary and the arc flash boundary are one and the same.
C: No unqualified person shall approach nearer than the restricted approach boundary of energized conductors and circuit parts.
D: No qualified person shall approach closer than the limited approach boundary of exposed energized electrical conductors or circuit parts.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.