NFPA 70E 120.4(A)(4) Simple Lockout/Tagout.

For the simple lockout/tagout, a written lockout/tagout plan is not required and there is never more than one source of electrical energy.
Click to Enlarge
For the simple lockout/tagout, a written lockout/tagout plan is not required and there is never more than one source of electrical energy.

According to 2018 NFPA 70E Section 120.2(I), two forms of hazardous electrical energy control are permitted:

For the simple lockout/tagout, a written lockout/tagout plan is not required and there is never more than one source of electrical energy. The qualified person performing the work is in charge and is responsible for their own lockout/tagout.

A complex lockout/tagout usually involves more than one source of energy and often involves more than one single disconnecting means. For the complex lockout/tagout, the person in charge shall have responsibility of the overall project and a written plan prepared before each lockout/tagout application.

Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.

120.4(A)(4) Simple Lockout/Tagout Procedure. All lockout/tagout procedures that involve only a qualified person(s) deenergizing one set of conductors or circuit part source for the sole purpose of safeguarding employees from exposure to electrical hazards shall be considered to be a simple lockout/ tagout. Simple lockout/tagout procedures shall not be required to be written for each application. Each worker shall be responsible for his or her own lockout/tagout.

Exception: Lockout/tagout is not required for work on cord- and plug connected equipment for which exposure to the hazards of unexpected energization of the equipment is controlled by the unplugging of the equipment from the energy source, provided that the plug is under the exclusive control of the employee performing the servicing and maintenance for the duration of the work.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

NFPA 70E 120.4(A)(4) Simple Lockout/Tagout.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true of the simple lockout/tagout procedure?

A: One worker shall be responsible for all other worker’s lockout/tagout.
B: A written lockout/tagout plan is required.
C: The qualified person doing the work shall be in charge.
D: The person in charge shall have responsibility of the overall project.