NFPA 70E 120.1 Lockout/Tagout Program & Responsibilities.

The lockout/tagout program must specify all required lockout/tagout procedures and practices.
Click to Enlarge
The lockout/tagout program must specify all required lockout/tagout procedures and practices.

It is the responsibility of the employer to establish, implement, and document a lockout/tagout program to safeguard workers from exposure to electrical hazards. The lockout/tagout program must specify all required lockout/tagout procedures and practices.

It is the responsibility of the employee to follow the lockout/tagout policy and all other safety procedures set forth by the employer.

Below is a sample of NFPA 70E. For the complete section, see the actual NFPA 70E text at NFPA.ORG. Once there, click on the free access link to NFPA 70E.

120.1 Lockout/Tagout Program.

(A) General. Each employer shall establish, document, and implement a lockout/tagout program. The lockout/tagout program shall specify lockout/tagout procedures to safeguard workers from exposure to electrical hazards. The lockout/ tagout program and procedures shall also incorporate the following:

(1) Be applicable to the experience and training of the workers and conditions in the workplace

(2) Meet the requirements of Article 120

(3) Apply to fixed, permanently installed equipment, temporarily installed equipment, and portable equipment

(B) Employer Responsibilities. The employer shall be responsible for the following:

(1) Providing the equipment necessary to execute lockout/ tagout procedures

(2) Providing lockout/tagout training to workers in accordance with 110.2

(3) Auditing the lockout/tagout program in accordance with 110.1

(4) Auditing execution of the lockout/tagout procedures in accordance with 110.1

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

NFPA 70E 120.1 Lockout/Tagout Program & Responsibilities.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding a lockout/tagout program?

A: The program applies to fixed, permanently installed equipment, temporarily installed equipment, and portable equipment.
B: The employee is responsible to provide all equipment necessary to execute lockout/ tagout procedures.
C: The employee is responsible to provide lockout/tagout training.
D: The program only applies to fixed in place equipment.
Please register or sign in for electrical continuing education courses.