210.70(C) Lighting Outlets Required. All Occupancies.

The pull-chain type luminaire is ok for this installation but since the switch control is not at the point of entry, there must also be a “wall switch” installed at the usual point of entry to the attic storage space.
Click to Enlarge
The pull-chain type luminaire is ok for this installation but since the switch control is not at the point of entry, there must also be a “wall switch” installed at the usual point of entry to the attic storage space.

Code Change Summary: Revisions were made to require lighting outlets in attics, underfloor spaces and basements of all occupancies.

This code section requires a careful read in order to apply it properly.

Until now, attics, underfloor spaces and basements in other than dwellings were required to have a lighting outlet only if these spaces contained equipment that required servicing such as HVAC units.

In the 2017 NEC®, this applies to dwellings and also includes areas used for storage. Now, attics, underfloor spaces, utility rooms, and basements, must have at least one lighting outlet containing a switch or controlled by a wall switch, located where these spaces are used for storage or contain equipment requiring servicing. At least one point of control must be at the usual point of entry to these spaces. The lighting outlet itself must be at or near the equipment requiring servicing.

Proper interpretation and application of this code section is key to avoiding the inspectors red tag.

Here are a few things to keep in mind in order to pass inspection:

Below is a preview of Article 210. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2017 NEC® edition of NFPA 70.

2014 Code Language:

210.70(C) Other Than Dwelling Units. For attics and underfloor spaces containing equipment requiring servicing, such as heating, air-conditioning, and refrigeration equipment, at least one lighting outlet containing a switch or controlled by a wall switch shall be installed in such spaces. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.

2017 Code Language:

210.70(C) All Occupancies. For attics and underfloor spaces, utility rooms, and basements, at least one lighting outlet containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment requiring servicing. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

210.70(C) Lighting Outlets Required. All Occupancies.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding attic lighting outlets?

A: Only commercial type occupancies require a lighting outlet in an attic used for storage.
B: An attic lighting outlet is only required for finished and habitable attics.
C: A dwelling unit attic being used only for storage requires a lighting outlet.
D: Lighting outlets in an attic are only required if equipment is located in the attic.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.