Article 725 Class 2 and Class 3 Power-Limited Circuits.

Article 725 shook loose, Article 722 picked up the cables.
Click to Enlarge

Article 725 shook loose, Article 722 picked up the cables.

Code Change Summary: Article 725 was significantly reduced as many former requirements were relocated into Article 722 as part of the Chapter 7 restructuring.

SME commentary: The 2026 NEC® revisions to Article 725 reflect the final stage of a broader restructuring that redistributed limited-energy requirements across newly created Chapter 7 articles. While earlier course sections addressed how limited-energy rules were extracted from Chapter 8 and reorganized into Articles 720 through 723, along with Articles 742 and 750, Article 725 illustrates the downstream effect of that reorganization on existing Article 725 content.

Historically, Article 725 served as a central location for a wide range of Class 2 and Class 3 power-limited circuit requirements, including wiring methods, cable installation rules, and system-level provisions that overlapped with communications and other limited-energy systems. As the NEC® transitioned away from Chapter 8’s stand-alone structure, and added more limited energy articles in Chapter 7, many of those overlapping requirements were intentionally pulled out of Article 725 and reassigned to Article 722 covering Limited-Energy Cables for Power-Limited Circuits, Fault-Managed-Power Circuits, Optical Fiber Circuits, and Communications Circuits.

As a result, Article 725 in the 2026 NEC® has been stripped down to only those provisions that remain uniquely applicable to Class 2 and Class 3 power-limited circuits. What once occupied several pages in prior editions has been reduced to the following three remaining code sections occupying less than a half of a page:

This reduction is not indicative of diminished importance of Class 2 and Class 3 circuits. Instead, it reflects a deliberate effort to eliminate duplication and place requirements in the most appropriate articles based on function and NEC® structure. Cable construction, wiring methods, overvoltage protection, grounding and bonding, and general installation rules are no longer repeated within Article 725 since they are now addressed in Article 722 that applies broadly across all limited-energy systems.

This restructuring improves usability by clarifying where requirements belong and reduces the risk of misapplication caused by overlapping or redundant code language.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Article 725 Class 2 and Class 3 Power-Limited Circuits.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following Article 725 code sections remains in the 2026 NEC?

A: Section 725.144 remains and covers ampacity of conductors.
B: Section 725.24 remains to cover mechanical execution of work.
C: Section 725.1 remains to provide the Scope of the article.
D: Section 725.136 remains to address circuit separation.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.