Article 210 Branch Circuits.

If the premises wiring system has branch circuits supplied from one nominal voltage system, branch circuit ungrounded conductors shall be identified in accordance with 310.6(A)(3).
Click to Enlarge

If the premises wiring system has branch circuits supplied from one nominal voltage system, branch circuit ungrounded conductors shall be identified in accordance with 310.6(A)(3).

Code Change Summary: Title change to Article 210 and new language on branch circuit identification.

SME commentary: In the 2026 NEC® editorial changes were made to the title of Article 210 to shorten the article title from “Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal” to simply “Branch Circuits”. This was a move by the Correlating Committee to align with similar article titles applicable to installations of 1000 volts ac, 1500 volts dc or less. Examples:

All of the above articles also have a counterpart article for applications Over 1000 Volts ac, 1500 Volts dc, Nominal as in the examples below:

Since “Over 1000 Volts ac, 1500 Volts dc, Nominal” is already part of the title in Articles 265 – 270, and the scopes of the articles clearly address the voltages covered by each article, the additional verbiage in the title of Article 210 was unnecessary.

Another noteworthy change is the addition of new language in 210.5(C)(1) to address branch circuit identification for installations where the premises wiring system only has branch circuits supplied from one nominal voltage system. When this is the case, branch circuit ungrounded conductors shall be identified in accordance with 310.6(A)(3) which requires ungrounded conductors, whether used as a single conductor or in multiconductor cables, to be finished to be clearly distinguishable from grounded conductors and equipment grounding conductors.

Before this new code language, Section 210.5(C) jumped straight into the branch circuit identification requirements for installations supplied from more than one nominal voltage system while offering no code language in this section for wiring systems where only one nominal voltage system is present. A similar change occurred for feeders in 215.12(C).

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2026 NEC® edition of NFPA 70.

2023 Code Language:

Article 210 Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal

2026 Code Language:

Article 210 Branch Circuits

N 210.5(C)(1) Branch Circuits Supplied from One Nominal Voltage System. Where the premises wiring system has branch circuits supplied from one nominal voltage system, branch circuit ungrounded conductors shall be identified in accordance with 310.6(A)(3).

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Article 210 Branch Circuits.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

What does 210.5(C)(1) require for ungrounded branch circuit conductors in a single nominal voltage system in the 2026 NEC?

A: They must be installed in separate raceways.
B: They must be identified using color codes from Article 300.
C: They must be identified as specified in 310.6(A)(3).
D: They must have a unique circuit directory label.
Please register or sign in for electrical continuing education courses.