Limited Energy cables include Class 2 circuits, Class 3 circuits, Class 4 circuits, Optical fiber systems, Communications circuits, CATV, Network-powered broadband low-power communications circuits, Premises communications circuits, Power-limited fire alarm circuits.
Code Change Summary: New definition of a Limited Energy Cable added to Article 100.
SME commentary: The 2026 NEC® introduces a new definition for "Limited-Energy Cable" in Article 100, a much-needed clarification aimed at standardizing the terminology surrounding limited-energy systems. This change provides an all-encompassing term that simplifies code application and enhances usability across multiple NEC® articles in Chapter 7 pertaining to communications, power-limited fire alarm systems, optical fiber circuits, and Class 2, Class 3, and Class 4 circuits.
In the 2026 NEC®, Article 100 now defines a Limited-Energy Cable as a factory made assembly of one or more conductors or optical fibers used for any of the following:
Prior to this revision, multiple NEC® articles referenced these cables individually, creating potential confusion regarding which rules applied to which types of cables. By establishing a unified definition, the NEC® eliminates ambiguity, enhances code usability, and simplifies the language and application of limited-energy articles.
This definition ensures that all qualifying low-voltage cables are recognized under the limited-energy umbrella, streamlining compliance and making it easier for designers, installers, and inspectors to apply NEC® requirements consistently. This update reflects the NEC’s ongoing commitment to clarity and modernization, addressing evolving electrical systems and their unique installation needs.
Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2026 NEC® edition of NFPA 70.
2023 Code Language:
Article 100 Definitions.
The definition did not exist.
2026 Code Language:
Article 100 Definitions.
N Cable, Limited-Energy. (Limited-Energy Cable) A factory made assembly of one or more conductors or optical fibers used for any of the following:
(1) Class 2 circuits
(2) Class 3 circuits
(3) Class 4 circuits
(4) Optical fiber systems
(5) Communications circuits
(6) Community antenna television circuits (CATV)
(7) Network-powered broadband low-power communications circuits
(8) Premises communications circuits
(9) Power-limited fire alarm circuits
What is the primary purpose of the new definition for “Limited-Energy Cable” in the 2026 NEC?