90.3 Code Arrangement.

NEC Figure 90.3 before and after.
Click to Enlarge

NEC Figure 90.3 before and after.

Code Change Summary: Modifications made to integrate Chapter 8 into the overall structure of the code.

SME commentary: In the 2026 NEC®, a change in 90.3 was made regarding Chapter 8 which will also align with the movement to restructure the NEC® over the next two code cycles.

With this change, chapter 8 will no longer stand alone, and is included with Chapters 5, 6, and 7 in that it can supplement or modify the requirements in Chapters 1 through 8 (See modified figure 90.3).

The 2026 NEC® is now organized into an introduction and nine chapters. Chapters 1 through 4 provide general requirements, while Chapters 5 through 8 may supplement or amend the provisions of Chapters 1 through 8.

Historically, Chapter 8 has been exempted from the requirements of Chapters 1 through 7 unless specifically referenced within Chapter 8. This approach was rooted in past practices where communication systems were predominantly installed by utility companies in premises wiring or public utility easements. However, modern premises communications wiring is now installed in the same manner as other premises wiring, mostly by electricians or entities other than utility companies. Maintaining the exemption for Chapter 8 systems, while applying different requirements to other energy-limited systems, creates enforcement challenges and inconsistencies, despite the hazards being identical.

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2026 NEC® edition of NFPA 70.

2023 Code Language:

90.3 Code Arrangement. The Code has an introduction and nine chapters, as shown in Figure 90.3. Chapters 1-4 apply generally. Chapters 5-7 apply to special occupancies, special equipment, or other special conditions and may supplement or modify the requirements in Chapters 1-7.

Chapter 8 covers communications systems and is not subject to the requirements of Chapters 1 through 7 except where the requirements are specifically referenced in Chapter 8.

Chapter 9 includes tables that are applicable as referenced.

Informative annexes are not part of the requirements of the Code but are included for informational purposes only.

2026 Code Language:

90.3 Code Arrangement. The Code has an introduction and nine chapters, as shown in Figure 90.3. Chapters 1- 4 apply generally. Chapters 5-8 may supplement or modify the requirements in Chapters 1-8.

Chapter 9 includes tables that are applicable as referenced.

Informative annexes are not part of the requirements of the Code but are included for informational purposes only.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

90.3 Code Arrangement.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Based on the 2026 NEC structure, which of the following is true?

A: Chapter 8 is titled “Special Occupancies”.
B: Chapter 8 has been deleted from the NEC.
C: Chapter 8 is informational only and not enforceable.
D: Chapter 8 can supplement or modify the requirements in Chapters 1 through 8.
Please register or sign in for electrical continuing education courses.