Power Distribution in Oregon.

In Oregon, GFPE testing shall be conducted by a person(s) having proper training and experience required to perform and evaluate the results of such performance testing, in accordance with instructions that shall be provided with the equipment. A written record of this testing shall be made, signed by the person(s) performing this test, and shall be available to the authority having jurisdiction.
Click to Enlarge
In Oregon, GFPE testing shall be conducted by a person(s) having proper training and experience required to perform and evaluate the results of such performance testing, in accordance with instructions that shall be provided with the equipment. A written record of this testing shall be made, signed by the person(s) performing this test, and shall be available to the authority having jurisdiction.

When preparing for upcoming inspections of the power distribution system (service equipment, switchgear, panelboards, transformers) make sure that the plans you are working from are identical to the city approved plans that the inspector will be referencing during the inspection.

On a large project, there will usually be revisions to the approved plans and change orders that occur. If the one-line diagram for the power distribution has changed between the time that the city approved and stamped the plans and the time of the inspection, be sure to get city approval for the revisions. If the inspector arrives to find a 3,000-amp service installed but the city approved plans show a 2,000-amp service, the inspector will stop the inspection and will not proceed until the electrical engineer has resubmitted the revised plans and the city has approved the changes. This can take days.

Be mindful of any required tests that must be documented to show the inspector.

One of the most important performance tests for newly installed electrical equipment is GFPE (Ground-Fault Protection of Equipment) testing. Performance testing is typically done after the system is installed but before it is energized.

Not all equipment contains a GFPE device. For each service disconnect rated 1000 amperes or more, section 230.95 requires GFPE in solidly grounded wye electric services of more than 150 volts to ground but not exceeding 1000 volts phase-to-phase. This will apply to all 480/277-volt service disconnects rated 1000 amps or more. Similar language is found in 215.10 for feeder disconnects and 210.13 for branch circuit disconnects.

When GFPE is installed, section 230.95(C) requires specific performance testing to make sure the device is functioning as intended. The inspector will usually request any code required testing to be performed by a 3rd party who will provide documentation after the testing is complete.

In Oregon, this code section has been amended to allow the system to be tested by a person having proper training and experience required to perform and evaluate the results of such performance testing in accordance with the manufacturer instructions rather than demanding a primary current injection test.

Below is the amended Oregon code language pertaining to the performance testing required in 230.95(C).

NEC 230.95(C) Performance Testing. The ground-fault protection system shall be performance tested when first installed on site. This testing shall be conducted by a person(s) having proper training and experience required to perform and evaluate the results of such performance testing, in accordance with instructions that shall be provided with the equipment. A written record of this testing shall be made, signed by the person(s) performing this test, and shall be available to the authority having jurisdiction.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Power Distribution in Oregon.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Which of the following is true regarding the testing of GFPE?

A: Performance testing is NOT required.
B: Performance testing is NOT required on site if a test was done at the factory.
C: The ground-fault protection system shall be performance tested when first installed on site.
D: Performance testing must be done after the equipment has been energized.
Please register or sign in for electrical continuing education courses.