406.9(C) Bathtub and Shower Space.

The zone where receptacles are not permitted extends to the floor in the 2023 NEC.
Click to Enlarge
The zone where receptacles are not permitted extends to the floor in the 2023 NEC.

Code Change Summary: Revised code language provides clarity to the rules on receptacles near bathtubs and showers.

In the 2017 NEC®, code language in Section 406.9(C) simply stated that receptacles were not to be installed within or directly over a bathtub or shower stall. The 2017 language was subjective and vague. What was considered “directly over”?

The 2020 NEC® saw a revision in Section 406.9(C) which specified a zone where receptacles were not permitted to be installed around the bathtub or shower.

This revised language was intended to align with the installation requirements and dimensions for luminaires near bathtubs and shower stalls from Section 410.10(D). The 2020 code change to Section 406.9(C) made it clear that receptacles must not be installed closer than 3 feet horizontally from, and 8 feet vertically from the top of the bathtub rim or shower stall threshold. Unfortunately, this revised language made no mention of the area below the bathtub rim.

In the 2023 NEC®, Section 406.9(C) was modified to include the area inside of the tub and also the space outside of the tub, below the designated zone.

Now, receptacles are not permitted to be installed inside of the tub or shower or within 3 feet horizontally from the outside edge of the bathtub or shower stall, including the space outside the bathtub or shower stall space below the zone unless one of the exceptions applies (see image).

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2023 NEC® edition of NFPA 70.

2020 Code Language:

406.9(C) Bathtub and Shower Space. Receptacles shall not be installed within a zone measured 3 feet horizontally and 8 feet vertically from the top of the bathtub rim or shower stall threshold. The identified zone is all-encompassing and shall include the space directly over the tub or shower stall.

2023 Code Language:

406.9(C) Bathtub and Shower Space. Receptacles shall not be installed inside of the tub or shower or within a zone measured 3 feet horizontally from any outside edge of the bathtub or shower stall, including the space outside the bathtub or shower stall space below the zone.

The zone also includes the space measured vertically from the floor to 8 feet above the top of the bathtub rim or shower stall threshold. The identified zone is all-encompassing and shall include the space directly over the bathtub or shower stall and the space below this zone, but not the space separated by a floor, wall, ceiling, room door, window, or fixed barrier.

Check all exceptions!

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

406.9(C) Bathtub and Shower Space.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Based on the 2023 NEC, which of the following is true?

A: Receptacles are NOT permitted inside of the tub or shower or within 3 feet horizontally from the outside edge of the bathtub or shower stall, including the space outside the bathtub or shower stall space below the zone unless one of the exceptions applies.
B: Receptacles are permitted inside of the bathtub.
C: Receptacles are permitted inside of the shower.
D: Receptacles are NOT permitted inside any bathroom.