Code Change Summary: The scope of Article 100 has been revised.
The global change in the 2023 NEC® to locate all NEC® definitions to Article 100 created the need to modify the scope of the Article.
The previous language stating that “definitions are also found in XXX.2 sections of other articles”, has been deleted and the second paragraph that speaks of the subdivided parts of Article 100 is gone.
A new last sentence was added to the scope of Article 100 that states “an article number in parentheses following the definition indicates that the definition only applies to that article”.
An example of this is the term “Adapter” in Article 100 as seen below. This term was previously defined in NEC® Section 520.2 since it was only used in Article 520. Now that it has been relocated to Article 100, having the applicable code article shown in parentheses after the definition tells the code user that this definition is only applicable to Article 520.
Adapter. A device used to adapt a circuit from one configuration of an attachment plug or receptacle to another configuration with the same current rating. (520) (CMP 15)
Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2023 NEC® edition of NFPA 70.
2020 Code Language:
Article 100 Scope. This article contains only those definitions essential to the application of this Code. It is not intended to include commonly defined general terms or commonly defined technical terms from related codes and standards. In general, only those terms that are used in two or more articles are defined in Article 100. Definitions are also found in XXX.2 sections of other articles.
Part I of this article contains definitions intended to apply wherever the terms are used throughout this Code. Part II contains definitions applicable to installations and equipment operating at over 1000 volts, nominal. Part III contains definitions applicable to Hazardous (Classified) Locations.
2023 Code Language:
Article 100 Scope. This article contains only those definitions essential to the application of this Code. It is not intended to include commonly defined general terms or commonly defined technical terms from related codes and standards. An article number in parentheses following the definition indicates that the definition only applies to that article.
Which of the following is true of Article 100 in the 2023 NEC?
| Please register or sign in for electrical continuing education courses. If you were already signed in, your session probably expired, please sign back in. |