Article 100 Definitions. Show Windows.

The window above the show window is also included when determining the required receptacle spacing for a show window.
Click to Enlarge
The window above the show window is also included when determining the required receptacle spacing for a show window.

A Show Window is the area at the front of a store for displaying merchandise. The definition in NEC® Article 100 makes it clear that the show window also includes the area above the door.

The reason this is important is because the NEC® has specific rules for show windows:

Here is an example using the language above:

A group M (mercantile) occupancy has 46 linear feet of show window including the window area above the main entry door. This area will be using 20 ampere, 120-volt branch circuits to supply the receptacles serving the show window area.

To calculate the branch circuit load for the show window, multiply 200 VA by the length of the show window. 200 VA X 46 = 9200 VA. Now find the current by dividing 9200 VA by the circuit voltage of 120 volts. 9200 VA ÷ 120 volts = 76.66 amps or 77 amps.

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to NFPA 70.

Code Language:

Article 100 Definitions:

Show Window:  Any window, including windows above doors, used or designed to be used for the display of goods or advertising material, whether it is fully or partly enclosed or entirely open at the rear and whether or not it has a platform raised higher than the street floor level.

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Article 100 Definitions. Show Windows.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

What is the branch circuit load for a store with 18 linear feet of show window where 120-volt branch circuits supply the required show window receptacles?

A: 432,000 VA.
B: 30 VA.
C: 3600 VA.
D: 2160 VA.