OESC 210.12(B) Arc-Fault Circuit-Interrupter Protection.

In Oregon, AFCI protection is not required on branch circuits supplying receptacles located in hallways.
Click to Enlarge
In Oregon, AFCI protection is not required on branch circuits supplying receptacles located in hallways.

Oregon has heavily amended the code language below regarding AFCI protection:

OESC 210.12(B) Dwelling Units. All 120-volt, single phase, 10-, 15- and 20-ampere branch circuits supplying outlets or devices installed in the following locations shall be protected by any of the means described in 210.12(A)(1) through (A)(6):

Items (1) through (13) remain unchanged.

(14) Similar areas Not adopted by the State of Oregon

(15) Alcoves

Exception No. 1: AFCI protection shall not be required for an individual branch circuit supplying a fire alarm system installed in accordance with 760.41(B) or 760.121(B). The branch circuit shall be installed in a metal raceway, metal auxiliary gutter, steel-armored cable, Type MC or Type AC, meeting the applicable requirements of 250.118, with metal boxes, conduit bodies, and enclosures.

Exception No. 2: AFCI protection shall not be required on branch circuits supplying receptacles located in hallways, kitchens or laundry areas and GFCI protected receptacles installed in dining rooms.

Exception No. 3: AFCI protection shall not be required for optional, dedicated outlets that supply equipment known to cause unwanted tripping of AFCI devices.

Exception No 4: AFCI protection shall not be required for branch circuits that serve an appliance that is not easily moved or that is fastened in place.

Oregon amendments to the 2023 NEC® are located in “Table 1-E” of the Oregon Electrical Specialty Code (OESC) which can be seen using the following link or the OESC PDF file located near the bottom of the screen: 2023 OESC

  Click here to view the OESC  

Did You Like This? Follow us on Face Book! Thanks!

Electrical License Renewal Facebook Logo

OESC 210.12(B) Arc-Fault Circuit-Interrupter Protection.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

In Oregon, which of the following is true of a single-phase, 120-volt, 15-amp, branch circuit supplying outlets in a dwelling unit hallway?

A: It requires GFCI protection.
B: AFCI protection is not required.
C: It cannot be used to supply a switched receptacle.
D: It can be used to supply a 20-amp rated receptacle.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.