Occupancy Classifications. Assembly Group A.

Group A-3 can include places of religious worship.
Click to Enlarge
Group A-3 can include places of religious worship.

NEC Article 518 provides wiring requirements for places of assembly (Assembly Occupancies).

According to the NEC®, the provisions of Article 518 apply to all buildings or portions of buildings or structures designed or intended for the gathering together of 100 or more persons for such purposes as deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation, or similar purposes. These are considered assembly occupancies according to the NEC®.

NEC Section 518.4 covers wiring methods permitted in an assembly occupancy including rated and non-rated construction as well as spaces with a specific finish rating identified in listings of fire-rated assemblies.

In addition, NEC® 700.10 and 700.12 have specific rules for emergency system fire protection and sources of emergency power that affect the electrician.

Identifying an assembly occupancy is critical for an electrician hired to perform electrical work in such places. The NEC® does not go into great detail on all of the different types of assembly occupancies but the International Building Code (IBC) does.

According to IBC Section 303, Assembly occupancies include groups A-1, A-2, A-3, A-4, and A-5 which are summarized below.


Group A-1 occupancy includes assembly uses, usually with fixed seating, intended for the production and viewing of the performing arts or motion pictures including, but not limited to:


Group A-2 occupancy includes assembly uses intended for food and/or drink consumption including, but not limited to:


Group A-3 occupancy includes assembly uses intended for worship, recreation or amusement and other assembly uses not classified elsewhere in Group A including, but not limited to:


Group A-4 occupancy includes assembly uses intended for viewing of indoor sporting events and activities with spectator seating including, but not limited to:


Group A-5 occupancy includes assembly uses intended for participation in or viewing outdoor activities including, but not limited to:

 

Did You Like This?   Follow us on Facebook!

Help Us Keep Our Knowledge Free!

Electrical License Renewal Facebook Logo

Occupancy Classifications. Assembly Group A.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

According to the NEC, which of the following is true regarding a place of assembly?

A: NEC Article 518 applies to a building intended for the gathering together of 50 or more persons.
B: NEC Article 518 applies to a structure intended for the gathering together of 40 or more persons.
C: NEC Article 518 applies to a portion of a building intended for the gathering together of 80 or more persons.
D: NEC Article 518 applies to all buildings or portions of buildings or structures designed or intended for the gathering together of 100 or more persons for such purposes as deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation, or similar purposes.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.