2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E Utah Electrical Continuing Education Course

2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E

Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians License Renewal.

Yes! We Are Approved by the Utah Division of Occupational & Professional Licensing for Utah Electricians' License Renewal.

Electrical Course Name Credit Hours Credit Type Course Number Course Availability Course Price
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E12.0 Core 19147 5/24/2022
-through-
5/23/2024
$129
-54

$75
This 12 Hour Utah Electrical Continuing Education License Renewal Course reviews the most important National Electrical Code changes from the 2020 NEC. From Article 100 all the way to Chapter 7 will be covered. In addition, a 4-hour module of Electrical Safety NFPA 70E is also included. Approved by the UT DOPL electrical board for you to renew in 2020.
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E Course Topics:
  Article 100 Fault Current & Available Fault Current.
  Article 100 Free Air (as applied to conductors).
  110.12(C) Mechanical Execution of Work. Cables and Conductors.
  110.22(A) Identification of Disconnecting Means. General.
  110.24(A) Field Marking.
  210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
  210.8(A) GFCI Protection. Dwelling Units.
  210.8(B) GFCI Protection. Other Than Dwelling Units.
  210.8(D) GFCI Protection for Specific Appliances.
  210.8(E) Equipment Requiring Servicing.
  210.8(F) GFCI Protection. Outdoor Outlets.
  210.12(D) AFCI Protection. Branch Circuit Extensions or Modifications in Dwelling Units, Dormitory Units, Guest Rooms and Guest Suites.
  210.19(A)(1) Branch Circuits.
  210.52(C) Countertops and Work Surfaces.
  210.52(C)(2) Island and Peninsular Countertops and Work Surfaces.
  210.63 Equipment Requiring Servicing.
  230.46 Spliced and Tapped Conductors.
  230.62 Service Equipment Barriers.
  230.66 Marking.
  230.67 Surge Protection.
  230.75 Disconnection of Grounded Conductor.
  230.85 Emergency Disconnects.
  240.6 Restricted Access Adjustable-Trip Circuit Breakers.
  240.33 Vertical Position.
  240.62 Reconditioned Equipment.
  240.86 Series Ratings and Motor Contribution.
  250.64(A) Aluminum or Copper-Clad Aluminum Conductors.
  250.104(A) Metal Water Piping.
  310.12 Single-Phase Dwelling Services and Feeders.
  310.15(B) Ambient Temperature Correction Factors.
  314.16(B)(5) Equipment Grounding Conductor Fill.
  314.27(C) Boxes at Ceiling-Suspended (Paddle) Fan Outlets.
  334.104 Conductors.
  338.10(B)(4) Installation Methods for Branch Circuits and Feeders.
  406.12 Tamper-Resistant Receptacles.
  406.13 Single-Pole Separable-Connector Type.
  408.6 Short-Circuit Current Rating.
  408.8 Reconditioning of Equipment.
  408.18(C) Connections.
  408.43 Panelboard Orientation.
  410.69 Identification of Control Conductor Insulation.
  410.118 Access to Other Boxes.
  410 Part XVI. Special Provisions for Horticultural Lighting Equipment.
  590.4(G) Splices.
  680.21(C) & 680.21(D) GFCI Protection.
  690.12(B)(2) Rapid Shutdown. Inside the Array Boundary.
  700.12(I)(2) Installation of Unit Equipment.
  700.16 Emergency Illumination.
  705.12 Load-Side Source Connections.
  725.144(B) Use of Class 2-LP or Class 3-LP Cables to Transmit Power and Data.

Safety (NFPA 70E)
  NFPA 70E Purpose and Scope.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E Article 100 Definitions.
  NFPA 70E 110.5(I) Job Safety Planning and Job Briefing.
  NFPA 70E 110.6(A)(1) Training Requirements. Qualified Person.
  NFPA 70E 110.8 Test Instruments and Equipment.
  NFPA 70E 110.8(E) Operation Verification.
  NFPA 70E 120.4(A)(4) Simple Lockout/Tagout Procedure.
  NFPA 70E 120.4(A)(5) Complex Lockout/Tagout.
  NFPA 70E 120.4(B)(1-3) Elements of Control.
  NFPA 70E 120.4(B)(4-6) Elements of Control.
  NFPA 70E 120.4(B)(7) Temporary Protective Grounding.
  NFPA 70E 120.4(B)(11) Lockout/Tagout Application.
  NFPA 70E 120.5(1-6) Process for Establishing and Verifying an Electrically Safe Work Condition.
  NFPA 70E 120.5(7) Testing for Absence of Voltage.
  NFPA 70E 130.2(B) Elements of an Energized Electrical Work Permit.
  NFPA 70E 130.4(E) Shock Protection Boundaries.
  NFPA 70E 130.4(E)(a) Shock Protection Approach Boundaries.
  NFPA 70E 130.5(C) Estimate of the Likelihood of Occurrence of an Arc Flash Incident for ac and dc Systems. Exercise 1.
  NFPA 70E 130.7(C)(15)(a) Arc-Flash Hazard PPE Categories for Alternating Current (ac) Systems. Exercise 1.
  NFPA 70E 130.7(C)(15)(c) Protective Clothing and Personal Protective Equipment (PPE).
New? First Time? Register for courses for free.

Returning For More? Sign In To Your Account
Other UT Electricians took these electrical continuing education courses with us:
Click on a banner below to go to the page for that course
2020 NEC Updates - 16 Hours w/4hrs NFPA 70E Banner
2020 NEC Updates - 16 Hours w/4hrs NFPA 70E
Course #: 19001
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2023 NEC Update - 16 Hours w/4Hrs NFPA 70E Banner
2023 NEC Update - 16 Hours w/4Hrs NFPA 70E
Course #: 20225
Credit Type: Core
Credit Hours: 16.0
Price: $149
 
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E Banner
2020 NEC Changes - 12 Hours w/4Hrs NFPA 70E
Course #: 19147
Credit Type: Core
Credit Hours: 12.0
Price: $129
 
2020 NEC Changes - 8 Hours Top Changes w/4Hrs NFPA 70E Banner
2020 NEC Changes - 8 Hours Top Changes w/4Hrs NFPA 70E
Course #: 19155
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
Available Fault Current Banner
Available Fault Current
Course #: 19501
Credit Type: Core
Credit Hours: 4.0
Price: $69
 
2020 NEC Changes - 8 Hours Pt 1 w/4Hrs NFPA 70E Banner
2020 NEC Changes - 8 Hours Pt 1 w/4Hrs NFPA 70E
Course #: 19151
Credit Type: Core
Credit Hours: 8.0
Price: $99
 
2020 NEC Changes - 8 Hours Pt 2 w/4Hrs NFPA 70E Banner
2020 NEC Changes - 8 Hours Pt 2 w/4Hrs NFPA 70E
Course #: 19153
Credit Type: Core
Credit Hours: 8.0
Price: $99