511.3(C) Repair Garages, Major and Minor.

New Table 511.3(C). Notice that all locations in the table are Class I locations. The Division or zone is what needs to be determined.
Click to Enlarge
New Table 511.3(C). Notice that all locations in the table are Class I locations. The Division or zone is what needs to be determined.

Code Change Summary: Requirements for major and minor repair garages have been completely reworked.

In order to align with NFPA 30A-2015 Code for Motor Fuel Dispensing Facilities and Repair Garages, the language in Section 511.3(C) has been completely rewritten with new language covering both major and minor repair garages where vehicles (using heavier than air gaseous Class I liquids) are repaired. As well, a new Table was added that sums up the requirements. New Table 511.3(C) is a replica of the corresponding portion of Table 8.3.2 of NFPA 30A.

Many of the requirements in the new table are the same requirements previously found within the text of Article 511 in the 2014 NEC®. Now, they are simply found in the format of a table instead.

Not all repair garages service vehicles that use special fuels. For those that do, there are several factors to be considered in order to ensure a safe environment.

Some flammable liquids such as liquid propane (LP) are heavier than air while others such as hydrogen or natural gas are lighter than air. Heavier than air fuels tend to congregate at the floor level of the repair garage where concentrations are at their greatest. Lighter than air fuels tend to congregate at the ceiling level of a repair garage. Wherever the fuel vapors congregate is where the risk of explosion is at its greatest. This code section is about vehicles that use fuels heavier than air.

See the new Table 511.3(C) to determine the Extent of Classified Locations for Major and Minor Repair Garages with Heavier-Than-Air Fuel.

Below is a preview of the NEC®. See the actual NEC® text at NFPA.ORG for the complete code section. Once there, click on their link to free access to the 2017 NEC® edition of NFPA 70.

2017 Code Language:

511.3(C) Repair Garages, Major and Minor. Where vehicles using Class I liquids or heavier-than-air gaseous fuels (such as LPG) are repaired, hazardous area classification guidance is found in Table 511.3(C).

Did You Like This? Let Us Know With A Like! Thanks!

511.3(C) Repair Garages, Major and Minor.

Below is a Real Question from our Electrical Continuing Education Courses for Electrical License Renewal:

Refer to the image. What is the classification of an unventilated, below grade pit, in a minor repair garage where Class I liquids are not transferred?

A: Class II Division 2.
B: Class II Division 1.
C: Class I Division 2.
D: Class I Division 1.
Please register or sign in for electrical continuing education courses.

If you were already signed in, your session probably expired, please sign back in.